2014Brazilian Journal of Anesthesiology (English Edition)Open access

Preanesthetic assessment data do not influence the time for tracheal intubation with Airtraq™ video laryngoscope in obese patients

Dante Ranieri, Fabio Zinelli, Adecir Geraldo Neubauer, Andre P. Schneider, Paulo do Nascimento

Open full text 10 citations

Abstract

PURPOSE: this study investigated the influence of anatomical predictors on difficult laryngoscopy and orotracheal intubation in obese patients by comparing Macintosh and Airtraq™ laryngoscopes. METHODS: from 132 bariatric surgery patients (body mass index ≥ 35 kgm(-1)), cervical perimeter, sternomental distance, interincisor distance, and Mallampati score were recorded. The patients were randomized into two groups according to whether a Macintosh (n=64) or an Airtraq™ (n=68) laryngoscope was used for tracheal intubation. Time required for intubation was the first outcome. Cormack-Lehane score, number of intubation attempts, the Macintosh blade used, any need for external tracheal compression or the use of gum elastic bougie were recorded. Intubation failure and strategies adopted were also registered. RESULTS: intubation failed in two patients in the Macintosh laryngoscope group, and these patients were included as worst cases scenario. The intubation times were 36.9+22.8s and 13.7+3.1s for the Macintosh and Airtraq™ laryngoscope groups (p<0.01), respectively. Cormack-Lehane scores were also lower for the Airtraq™ group. One patient in the Macintosh group with intubation failure was quickly intubated with the Airtraq™. Cervical circumference (p<0.01) and interincisor distance (p<0.05) influenced the time required for intubation in the Macintosh group but not in the Airtraq™ group. CONCLUSION: in obese patients despite increased neck circumference and limited mouth opening, the Airtraq™ laryngoscope affords faster tracheal intubation than the Macintosh laryngoscope, and it may serve as an alternative when conventional laryngoscopy fails.

About this research paper

What this paper is about

PURPOSE: this study investigated the influence of anatomical predictors on difficult laryngoscopy and orotracheal intubation in obese patients by comparing Macintosh and Airtraq™ laryngoscopes. METHODS: from 132 bariatric surgery patients (body mass index ≥ 35 kgm(-1)), cervical perimeter, sternomental distance, interincisor distance, and Mallampati score were recorded. The patients were randomized into two groups according to whether a Macintosh (n=64) or an Airtraq™ (n=68) laryngoscope was used for tracheal intubation. Time required for intubation was the first outcome. Cormack-Lehane score, number of intubation attempts, the Macintosh blade used, any need for external tracheal compression or the use of gum elastic bougie were recorded. Intubation failure and strategies adopted were also registered. RESULTS: intubation failed in two patients in the Macintosh laryngoscope group, and these patients were included as worst cases scenario. The intubation times were 36.9+22.8s and 13.7+3.1s for the Macintosh and Airtraq™ laryngoscope groups (p<0.01), respectively. Cormack-Lehane scores were also lower for the Airtraq™ group. One patient in the Macintosh group with intubation failure was quickly intubated with the Airtraq™. Cervical circumference (p<0.01) and interincisor distance (p<0.05) influenced the time required for intubation in the Macintosh group but not in the Airtraq™ group. CONCLUSION: in obese patients despite increased neck circumference and limited mouth opening, the Airtraq™ laryngoscope affords faster tracheal intubation than the Macintosh laryngoscope, and it may serve as an alternative when conventional laryngoscopy fails.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: this study investigated the influence of anatomical predictors on difficult laryngoscopy and orotracheal intubation in obese patients by comparing Macintosh and Airtraq™ laryngoscopes. METHODS: from 132 bariatric surgery patients (body mass index ≥ 35 kgm(-1)), cervical perimeter, sternomental distance, interincisor distance, and Mallampati score were recorded. The patients were randomized into two groups according to whether a Macintosh (n=64) or an Airtraq™ (n=68) laryngoscope was used for tracheal intubation. Time required for intubation was the first outcome. Cormack-Lehane score, number of intubation attempts, the Macintosh blade used, any need for external tracheal compression or the use of gum elastic bougie were recorded. Intubation failure and strategies adopted were also registered. RESULTS: intubation failed in two patients in the Macintosh laryngoscope group, and these patients were included as worst cases scenario. The intubation times were 36.9+22.8s and 13.7+3.1s for the Macintosh and Airtraq™ laryngoscope groups (p<0.01), respectively. Cormack-Lehane scores were also lower for the Airtraq™ group. One patient in the Macintosh group with intubation failure was quickly intubated with the Airtraq™. Cervical circumference (p<0.01) and interincisor distance (p<0.05) influenced the time required for intubation in the Macintosh group but not in the Airtraq™ group. CONCLUSION: in obese patients despite increased neck circumference and limited mouth opening, the Airtraq™ laryngoscope affords faster tracheal intubation than the Macintosh laryngoscope, and it may serve as an alternative when conventional laryngoscopy fails.

Key concepts: Medicine, Intubation, Laryngoscopes, Tracheal intubation, Laryngoscopy, Anesthesia, Orotracheal intubation, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Preanesthetic assessment data do not influence the time for tracheal intubation with Airtraq™ video laryngoscope in obese patients — Research Paper | ScholarLens