Assessment of Dialysis Adequacy Using the Dialysate Urea Monitor: Preliminary Experience of the Dialysate Urea Monitor

Wen-Chen Lee, Chi-Jen Tsai, Chiu‐Ching Huang, Ching-Chang Lee, Yu-Shu Chien, Sau-An Hu, Ching‐Herng Wu

Open full text 5 citations

Abstract

Numerous studies have identified a strong linkage between the delivered dialysis dose (Kt/V) and the survival of hemodialysis (HD) patients. However, the current method used to calculate Kt/V requires multiple blood samples and the process is complex and time consuming. We evaluate the performance of a recently developed on-line monitor (Biostat 1000 dialysate urea monitor, Baxter) that measures the urea concentration in the effluent dialysate and displays Kt/V and nPCR immediately after hemodialysis. To verify the performance of the urea monitor, we selected 21 hemodialysis patients, calculated their Kt/V and nPCR values from blood samples obtained during each hemodialysis, and compared the results with data obtained using the urea monitor. The Kt/V and nPCR values calculated by the urea monitor were both significantly correlated with those obtained using blood samples (R = 0.804, p < 0.001 in Kt/V and R = 0.749, p < 0.001 in nPCR). Our results suggest that the urea monitor may be used for on-line assessment of dialysis adequacy and obviates the need for blood sampling.

Open-access reader

About this research paper

What this paper is about

Numerous studies have identified a strong linkage between the delivered dialysis dose (Kt/V) and the survival of hemodialysis (HD) patients. However, the current method used to calculate Kt/V requires multiple blood samples and the process is complex and time consuming. We evaluate the performance of a recently developed on-line monitor (Biostat 1000 dialysate urea monitor, Baxter) that measures the urea concentration in the effluent dialysate and displays Kt/V and nPCR immediately after hemodialysis. To verify the performance of the urea monitor, we selected 21 hemodialysis patients, calculated their Kt/V and nPCR values from blood samples obtained during each hemodialysis, and compared the results with data obtained using the urea monitor. The Kt/V and nPCR values calculated by the urea monitor were both significantly correlated with those obtained using blood samples (R = 0.804, p < 0.001 in Kt/V and R = 0.749, p < 0.001 in nPCR). Our results suggest that the urea monitor may be used for on-line assessment of dialysis adequacy and obviates the need for blood sampling.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Numerous studies have identified a strong linkage between the delivered dialysis dose (Kt/V) and the survival of hemodialysis (HD) patients. However, the current method used to calculate Kt/V requires multiple blood samples and the process is complex and time consuming. We evaluate the performance of a recently developed on-line monitor (Biostat 1000 dialysate urea monitor, Baxter) that measures the urea concentration in the effluent dialysate and displays Kt/V and nPCR immediately after hemodialysis. To verify the performance of the urea monitor, we selected 21 hemodialysis patients, calculated their Kt/V and nPCR values from blood samples obtained during each hemodialysis, and compared the results with data obtained using the urea monitor. The Kt/V and nPCR values calculated by the urea monitor were both significantly correlated with those obtained using blood samples (R = 0.804, p < 0.001 in Kt/V and R = 0.749, p < 0.001 in nPCR). Our results suggest that the urea monitor may be used for on-line assessment of dialysis adequacy and obviates the need for blood sampling.

Key concepts: Medicine, Hemodialysis, Urea, Kt/V, Dialysis, Dialysis adequacy, Urology, Internal medicine