2008Journal of Pediatric Hematology/OncologyRequires access

Dyshemoglobinemias and Pulse Oximetry

Anne Hladik, Kecha Lynshue

Open publisher page 22 citations

Abstract

Pulse oximetry normally provides a reliable indicator of arterial blood oxygen saturation. Individuals with a variant hemoglobin with low oxygen affinity would exhibit pulse oximetry values consistent with hypoxemia despite maintaining adequate oxygen delivery to tissues. We describe a patient we diagnosed with hemoglobin Rothschild and his mother. He presented with SpO2 81% on pulse oximetry and PaO2 on arterial blood gas of 47 mm Hg, while his mother had SpO2 87%. These values were significantly lower than physical examination suggested. A possible dyshemoglobinemia should be suspected when discordance exists between pulse oximetry readings and physical examination findings.

About this research paper

What this paper is about

Pulse oximetry normally provides a reliable indicator of arterial blood oxygen saturation. Individuals with a variant hemoglobin with low oxygen affinity would exhibit pulse oximetry values consistent with hypoxemia despite maintaining adequate oxygen delivery to tissues. We describe a patient we diagnosed with hemoglobin Rothschild and his mother. He presented with SpO2 81% on pulse oximetry and PaO2 on arterial blood gas of 47 mm Hg, while his mother had SpO2 87%. These values were significantly lower than physical examination suggested. A possible dyshemoglobinemia should be suspected when discordance exists between pulse oximetry readings and physical examination findings.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pulse oximetry normally provides a reliable indicator of arterial blood oxygen saturation. Individuals with a variant hemoglobin with low oxygen affinity would exhibit pulse oximetry values consistent with hypoxemia despite maintaining adequate oxygen delivery to tissues. We describe a patient we diagnosed with hemoglobin Rothschild and his mother. He presented with SpO2 81% on pulse oximetry and PaO2 on arterial blood gas of 47 mm Hg, while his mother had SpO2 87%. These values were significantly lower than physical examination suggested. A possible dyshemoglobinemia should be suspected when discordance exists between pulse oximetry readings and physical examination findings.

Key concepts: Pulse oximetry, Medicine, Hypoxemia, Arterial blood, Oxygen saturation, Pulse (music), Hemoglobin, Oxygen delivery

Related papers

Back to paper searchBrowse research topicsOriginal source
Dyshemoglobinemias and Pulse Oximetry — Research Paper | ScholarLens