Artemisinin evaluation in RomanianArtemisia annuawild plants using a new HPLC/MS method
Bianca Ivănescu, Laurian Vlase, Andreia Corciovă, Mihai Lazăr
Abstract
Bianca Ivănescu, Laurian Vlase, Andreia Corciovă, Mihai Lazăr
Abstract
Artemisinin, a sesquiterpene lactone from Artemisia annua L., has received considerable attention in the last few decades as a potent antimalarial drug. Artemisinin has rather low toxicity; it is effective against drug-resistant Plasmodium species and against cerebral malaria. This study reports the development of a rapid and sensitive assay for the quantification of artemisinin in A. annua by reversed phase HPLC/MS. In the selected optimal experimental conditions, artemisinin exhibited a well-defined chromatographic peak with a retention time of 2 ± 0.2 min. The chromatographic signal shows a linear dependence with artemisinin concentration, enabling the use of this signal for artemisinin quantification according to the following regression equation: y = 2665.40x - 14697.61. The correlation coefficient (R(2)) was 0.9989. For every concentration within the range of the standard curve (0.1-2 µg mL(-1)), accuracy was between 95 and 104%. Artemisinin content in Romanian A. annua wild plants varies between 0.17 and 0.21% (dry weight basis).
OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Artemisinin, a sesquiterpene lactone from Artemisia annua L., has received considerable attention in the last few decades as a potent antimalarial drug. Artemisinin has rather low toxicity; it is effective against drug-resistant Plasmodium species and against cerebral malaria. This study reports the development of a rapid and sensitive assay for the quantification of artemisinin in A. annua by reversed phase HPLC/MS. In the selected optimal experimental conditions, artemisinin exhibited a well-defined chromatographic peak with a retention time of 2 ± 0.2 min. The chromatographic signal shows a linear dependence with artemisinin concentration, enabling the use of this signal for artemisinin quantification according to the following regression equation: y = 2665.40x - 14697.61. The correlation coefficient (R(2)) was 0.9989. For every concentration within the range of the standard curve (0.1-2 µg mL(-1)), accuracy was between 95 and 104%. Artemisinin content in Romanian A. annua wild plants varies between 0.17 and 0.21% (dry weight basis).
Key concepts: Artemisinin, Artemisia annua, Sesquiterpene lactone, Chromatography, Chemistry, High-performance liquid chromatography, Plasmodium falciparum, Sesquiterpene