1999RespirationRequires access

Comparison of the Bronchodilator Effects of Salbutamol Delivered via a Metered-Dose Inhaler with Spacer, a Dry-Powder Inhaler, and a Jet Nebulizer in Patients with Chronic Obstructive Pulmonary Disease

Akihiko Ikeda, Koichi Nishimura, Hiroshi Koyama, Mitsuhiro Tsukino, Takashi Hajiro, Michiaki Mishima, Takateru Izumi

Open publisher page 29 citations

Abstract

The aim of this study was to compare the bronchodilator effects of salbutamol delivered via three different devices: a dry-powder inhaler (DPI), a metered-dose inhaler (MDI) with a large-volume spacer and a jet nebulizer (NEB) in patients with stable chronic obstructive pulmonary disease (COPD). Ten male patients with stable COPD [age: 67.2 +/- 3.8 years, forced expiratory volume in 1 s (FEV1): 1.56 +/- 0.32 liters] were studied in a randomized, double-blind and crossover manner. Each patient received 200 or 1, 000 microg salbutamol via an MDI with an InspirEaseTM spacer, a RotahalerTM, or a DeVilbiss 646(TM) nebulizer (NEB), or matching placebo on 7 separate days. Spirometry was performed before and 15, 30, 60, 90, 120, and 240 min after inhalation. With the 200- microg dose, only DPI produced a small but greater response in maximum FEV1 and in area under the time-response curve (AUC-FEV1) compared with placebo. With the 1,000- microg dose, DPI and MDI produced equally greater improvements in both maximum FEV1 and AUC-FEV1 than NEB. An equal bronchodilating effect can be obtained using either DPI or MDI with a spacer device, whereas the NEB was less effective when the same dose was administered.

About this research paper

What this paper is about

The aim of this study was to compare the bronchodilator effects of salbutamol delivered via three different devices: a dry-powder inhaler (DPI), a metered-dose inhaler (MDI) with a large-volume spacer and a jet nebulizer (NEB) in patients with stable chronic obstructive pulmonary disease (COPD). Ten male patients with stable COPD [age: 67.2 +/- 3.8 years, forced expiratory volume in 1 s (FEV1): 1.56 +/- 0.32 liters] were studied in a randomized, double-blind and crossover manner. Each patient received 200 or 1, 000 microg salbutamol via an MDI with an InspirEaseTM spacer, a RotahalerTM, or a DeVilbiss 646(TM) nebulizer (NEB), or matching placebo on 7 separate days. Spirometry was performed before and 15, 30, 60, 90, 120, and 240 min after inhalation. With the 200- microg dose, only DPI produced a small but greater response in maximum FEV1 and in area under the time-response curve (AUC-FEV1) compared with placebo. With the 1,000- microg dose, DPI and MDI produced equally greater improvements in both maximum FEV1 and AUC-FEV1 than NEB. An equal bronchodilating effect can be obtained using either DPI or MDI with a spacer device, whereas the NEB was less effective when the same dose was administered.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The aim of this study was to compare the bronchodilator effects of salbutamol delivered via three different devices: a dry-powder inhaler (DPI), a metered-dose inhaler (MDI) with a large-volume spacer and a jet nebulizer (NEB) in patients with stable chronic obstructive pulmonary disease (COPD). Ten male patients with stable COPD [age: 67.2 +/- 3.8 years, forced expiratory volume in 1 s (FEV1): 1.56 +/- 0.32 liters] were studied in a randomized, double-blind and crossover manner. Each patient received 200 or 1, 000 microg salbutamol via an MDI with an InspirEaseTM spacer, a RotahalerTM, or a DeVilbiss 646(TM) nebulizer (NEB), or matching placebo on 7 separate days. Spirometry was performed before and 15, 30, 60, 90, 120, and 240 min after inhalation. With the 200- microg dose, only DPI produced a small but greater response in maximum FEV1 and in area under the time-response curve (AUC-FEV1) compared with placebo. With the 1,000- microg dose, DPI and MDI produced equally greater improvements in both maximum FEV1 and AUC-FEV1 than NEB. An equal bronchodilating effect can be obtained using either DPI or MDI with a spacer device, whereas the NEB was less effective when the same dose was administered.

Key concepts: Medicine, Salbutamol, Nebulizer, Dry-powder inhaler, Bronchodilator, Metered-dose inhaler, COPD, Spirometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the Bronchodilator Effects of Salbutamol Delivered via a Metered-Dose Inhaler with Spacer, a Dry-Powder Inhaler, and a Jet Nebulizer in Patients with Chronic Obstructive Pulmonary Disease — Research Paper | ScholarLens