1994•Journal of Structural EngineeringRequires access

Equivalent Frame Analysis of Flat Plate Buildings for Seismic Loading

Y. H. Luo, Ahmad J. Durrani, Joel P. Conte

Open publisher page 26 citations

Abstract

An equivalent frame approach is presented for nonlinear seismic analysis of reinforced‐concrete flat plate buildings. The approach employs a parametric hysteretic model and is based on the effective slab‐width concept. Unlike in the previous equivalent frame approaches, the proposed method targets both the moment‐transfer capacity as well as stiffness of the interior and exterior slab‐column connections. The hysteretic parameters and the effective slab width factors are determined from results of laboratory tests on slab‐column connections for the class of flat plate buildings constructed prior to the 1960s with reinforcing detail typical of gravity load design. The validity of the approach is justified by comparing the calculated and the measured responses of two‐bay flat plate subassemblies tested under earthquake‐type loading. With the proposed equivalent frame approach, the response of flat plate buildings for seismic loading could be predicted more realistically over a wide range of lateral drift levels.

About this research paper

What this paper is about

An equivalent frame approach is presented for nonlinear seismic analysis of reinforced‐concrete flat plate buildings. The approach employs a parametric hysteretic model and is based on the effective slab‐width concept. Unlike in the previous equivalent frame approaches, the proposed method targets both the moment‐transfer capacity as well as stiffness of the interior and exterior slab‐column connections. The hysteretic parameters and the effective slab width factors are determined from results of laboratory tests on slab‐column connections for the class of flat plate buildings constructed prior to the 1960s with reinforcing detail typical of gravity load design. The validity of the approach is justified by comparing the calculated and the measured responses of two‐bay flat plate subassemblies tested under earthquake‐type loading. With the proposed equivalent frame approach, the response of flat plate buildings for seismic loading could be predicted more realistically over a wide range of lateral drift levels.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An equivalent frame approach is presented for nonlinear seismic analysis of reinforced‐concrete flat plate buildings. The approach employs a parametric hysteretic model and is based on the effective slab‐width concept. Unlike in the previous equivalent frame approaches, the proposed method targets both the moment‐transfer capacity as well as stiffness of the interior and exterior slab‐column connections. The hysteretic parameters and the effective slab width factors are determined from results of laboratory tests on slab‐column connections for the class of flat plate buildings constructed prior to the 1960s with reinforcing detail typical of gravity load design. The validity of the approach is justified by comparing the calculated and the measured responses of two‐bay flat plate subassemblies tested under earthquake‐type loading. With the proposed equivalent frame approach, the response of flat plate buildings for seismic loading could be predicted more realistically over a wide range of lateral drift levels.

Key concepts: Structural engineering, Slab, Parametric statistics, Stiffness, Moment (physics), Frame (networking), Geology, Structural load

Related papers

Back to paper searchBrowse research topicsOriginal source
Equivalent Frame Analysis of Flat Plate Buildings for Seismic Loading — Research Paper | ScholarLens