Blowdown hydraulic influence on core thermal response in LOFT nuclear experiment L2-3. [PWR]
D.L. Reeder
Abstract
Open-access reader
D.L. Reeder
Abstract
Open-access reader
Experimental research into pressurized water reactor (PWR) loss-of-coolant phenomena conducted in the Loss-of-Fluid Test (LOFT) facility has given results indicating that for very large pipe breaks the core thermal response is tightly coupled to the fluid hydraulic phenomena during the blowdown phase of the loss-of-coolant transient. This summary presents and discusses data supporting this conclusion. LOFT Loss-of-Coolant Experiment (LOCE) L2-3 simulated a complete double-ended offset shear break of a primary coolant reactor vessel inlet pipe in a commercial PWR. The LOFT system conditions at experiment initiation were: fuel rod maximum linear heat generation rate (MLHGR) of 39.4 +- 3 kW/m, hot leg temperature of 593 +- 3 K, core ..delta..T of 32.2 +- 4 K, system pressure of 15.06 +- 0.03 MPa, and flow rate/system volume of 25.6 +- 0.8 kg/m/sup 3/. These conditions are typical of those in commercial PWR systems at normal operating conditions.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Experimental research into pressurized water reactor (PWR) loss-of-coolant phenomena conducted in the Loss-of-Fluid Test (LOFT) facility has given results indicating that for very large pipe breaks the core thermal response is tightly coupled to the fluid hydraulic phenomena during the blowdown phase of the loss-of-coolant transient. This summary presents and discusses data supporting this conclusion. LOFT Loss-of-Coolant Experiment (LOCE) L2-3 simulated a complete double-ended offset shear break of a primary coolant reactor vessel inlet pipe in a commercial PWR. The LOFT system conditions at experiment initiation were: fuel rod maximum linear heat generation rate (MLHGR) of 39.4 +- 3 kW/m, hot leg temperature of 593 +- 3 K, core ..delta..T of 32.2 +- 4 K, system pressure of 15.06 +- 0.03 MPa, and flow rate/system volume of 25.6 +- 0.8 kg/m/sup 3/. These conditions are typical of those in commercial PWR systems at normal operating conditions.
Key concepts: Boiler blowdown, Coolant, Nuclear engineering, Thermal hydraulics, Pressurized water reactor, Scram, Heat transfer, Materials science