A New High-Throughput LC-MS/MS Assay for Therapeutic Level Monitoring of Valproic Acid in Human Plasma
Laurian Vlase
Abstract
Open-access reader
Laurian Vlase
Abstract
Open-access reader
A new high-throughput liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of valproic acid in human plasma was developed and validated. The separation was performed on a Zorbax SB-C18 column under isocratic conditions using a 48:52 (v/v) mixture of acetonitrile and 0.1% (v/v) acetic acid in water at 45 °C with a flow rate of 0.8 mL/min. The detection of valproic acid was performed in SIM mode (m/z 143.1). The human plasma samples (0.2 mL) were deproteinized with methanol and aliquots of 2 μL from supernatants obtained after centrifugation were directly injected into the chromatographic system. The method shows a good linearity (r > 0.9972), precision (CV > 7.8 %) and accuracy (bias > 5.7 %) over the range of 5-200 μg/mL plasma. Lower limit of quantification (LLOQ) was 5 μg/mL and the recovery was between 98-106 %. The method is not expensive, it needs a minimum time for plasma sample preparation and has a run-time of 2.4 min for instrument analysis (retention time of valproic acid was 1.8 min). The developed and validated high-throughput method is very simple, rapid and efficient, with wide applications in clinical level monitoring, pharmacokinetics and bioequivalence studies.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A new high-throughput liquid chromatographic tandem mass spectrometric (LC-MS/MS) assay for the quantification of valproic acid in human plasma was developed and validated. The separation was performed on a Zorbax SB-C18 column under isocratic conditions using a 48:52 (v/v) mixture of acetonitrile and 0.1% (v/v) acetic acid in water at 45 °C with a flow rate of 0.8 mL/min. The detection of valproic acid was performed in SIM mode (m/z 143.1). The human plasma samples (0.2 mL) were deproteinized with methanol and aliquots of 2 μL from supernatants obtained after centrifugation were directly injected into the chromatographic system. The method shows a good linearity (r > 0.9972), precision (CV > 7.8 %) and accuracy (bias > 5.7 %) over the range of 5-200 μg/mL plasma. Lower limit of quantification (LLOQ) was 5 μg/mL and the recovery was between 98-106 %. The method is not expensive, it needs a minimum time for plasma sample preparation and has a run-time of 2.4 min for instrument analysis (retention time of valproic acid was 1.8 min). The developed and validated high-throughput method is very simple, rapid and efficient, with wide applications in clinical level monitoring, pharmacokinetics and bioequivalence studies.
Key concepts: Chromatography, Chemistry, Bioanalysis, Bioequivalence, Human plasma, Valproic Acid, Detection limit, Acetic acid