2007Clinical ChemistryOpen access

Detection of Factor VIII Gene Mutations by High-Resolution Melting Analysis

Andrew D. Laurie, Mark P. Smith, Peter M. George

Open full text 45 citations

Abstract

BACKGROUND: Single base-pair substitution mutations in the gene for coagulation factor VIII, procoagulant component (hemophilia A) (F8) account for approximately 50% of severe cases of hemophilia A (HA), and almost all moderate or mild cases. Because F8 is a large gene, mutation screening using denaturing HPLC or DNA sequencing is time-consuming and expensive. METHODS: We evaluated high-resolution melting analysis as an option for screening for F8 gene mutations. The melting curves of amplicons heterozygous for known F8 gene mutations were compared with melting curves of the corresponding normal amplicons to assess whether melting analysis could detect these variants. We examined 2 platforms, the Roche LightCycler 480 (LC480) and the Idaho Technology LightScanner. RESULTS: On both instruments, 18 (90%) of the 20 F8 gene variants we examined were resolved by melting analysis. For the other 2 mutations, the melting curves of the heterozygous amplicons were similar to the corresponding normal amplicons, suggesting these variants may not be detected by this approach in a mutation-scanning screen. CONCLUSION: High-resolution melting analysis is an appealing technology for F8 gene screening. It is rapid and quickly identifies mutations in the majority of HA patients; samples in which no mutation is detected require further testing by DNA sequencing. The LC480 and LightScanner platforms performed similarly.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Single base-pair substitution mutations in the gene for coagulation factor VIII, procoagulant component (hemophilia A) (F8) account for approximately 50% of severe cases of hemophilia A (HA), and almost all moderate or mild cases. Because F8 is a large gene, mutation screening using denaturing HPLC or DNA sequencing is time-consuming and expensive. METHODS: We evaluated high-resolution melting analysis as an option for screening for F8 gene mutations. The melting curves of amplicons heterozygous for known F8 gene mutations were compared with melting curves of the corresponding normal amplicons to assess whether melting analysis could detect these variants. We examined 2 platforms, the Roche LightCycler 480 (LC480) and the Idaho Technology LightScanner. RESULTS: On both instruments, 18 (90%) of the 20 F8 gene variants we examined were resolved by melting analysis. For the other 2 mutations, the melting curves of the heterozygous amplicons were similar to the corresponding normal amplicons, suggesting these variants may not be detected by this approach in a mutation-scanning screen. CONCLUSION: High-resolution melting analysis is an appealing technology for F8 gene screening. It is rapid and quickly identifies mutations in the majority of HA patients; samples in which no mutation is detected require further testing by DNA sequencing. The LC480 and LightScanner platforms performed similarly.

Why it matters

OpenAlex reports 45 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Single base-pair substitution mutations in the gene for coagulation factor VIII, procoagulant component (hemophilia A) (F8) account for approximately 50% of severe cases of hemophilia A (HA), and almost all moderate or mild cases. Because F8 is a large gene, mutation screening using denaturing HPLC or DNA sequencing is time-consuming and expensive. METHODS: We evaluated high-resolution melting analysis as an option for screening for F8 gene mutations. The melting curves of amplicons heterozygous for known F8 gene mutations were compared with melting curves of the corresponding normal amplicons to assess whether melting analysis could detect these variants. We examined 2 platforms, the Roche LightCycler 480 (LC480) and the Idaho Technology LightScanner. RESULTS: On both instruments, 18 (90%) of the 20 F8 gene variants we examined were resolved by melting analysis. For the other 2 mutations, the melting curves of the heterozygous amplicons were similar to the corresponding normal amplicons, suggesting these variants may not be detected by this approach in a mutation-scanning screen. CONCLUSION: High-resolution melting analysis is an appealing technology for F8 gene screening. It is rapid and quickly identifies mutations in the majority of HA patients; samples in which no mutation is detected require further testing by DNA sequencing. The LC480 and LightScanner platforms performed similarly.

Key concepts: High Resolution Melt, Amplicon, Melting curve analysis, Mutation, Gene, Genetics, Gene mutation, Polymerase chain reaction

Related papers

Back to paper searchBrowse research topicsOriginal source
Detection of Factor VIII Gene Mutations by High-Resolution Melting Analysis — Research Paper | ScholarLens