2001Journal of Magnetic Resonance ImagingOpen access

Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agents

Hölger Thiele, Eike Nagel, Ingo Paetsch, Bernhard Schnackenburg, Axel Bornstedt, Marc Kouwenhoven, Andreas Wahl, Gerhard Schüler, Eckart Fleck

Open full text 217 citations

Abstract

Contrast between blood and myocardium in standard turbo gradient echo MR techniques (TFE) used routinely in clinical practice is mainly caused by unsaturated inflowing blood. Steady-state free precession (SSFP) has excellent contrast even in the absence of inflow effects. In 45 subjects cardiac cine loops in two long axis projections were acquired using TFE and compared with SSFP. A visual score (range 0 worst - 3 best) was assigned for endocardial border delineation for six myocardial segments in two long axis views. Endocardial border delineation score for TFE was 1.3 +/- 0.3 per segment and 2.4 +/- 0.3 for SSFP (P < 0.0001). Signal intensity blood/signal intensity myocardium was 1.5 +/- 0.4 at enddiastole and 1.4 +/- 0.3 at systole for TFE and 3.5 +/- 1.1 and 3.2 +/- 1.3 for SSFP, respectively (P < 0.0001). SSFP increases contrast between blood and myocardium more than twofold, resulting in an improved endocardial border definition. This may reduce variability for the determination of cardiac volumes and ejection fraction.

Open-access reader

About this research paper

What this paper is about

Contrast between blood and myocardium in standard turbo gradient echo MR techniques (TFE) used routinely in clinical practice is mainly caused by unsaturated inflowing blood. Steady-state free precession (SSFP) has excellent contrast even in the absence of inflow effects. In 45 subjects cardiac cine loops in two long axis projections were acquired using TFE and compared with SSFP. A visual score (range 0 worst - 3 best) was assigned for endocardial border delineation for six myocardial segments in two long axis views. Endocardial border delineation score for TFE was 1.3 +/- 0.3 per segment and 2.4 +/- 0.3 for SSFP (P < 0.0001). Signal intensity blood/signal intensity myocardium was 1.5 +/- 0.4 at enddiastole and 1.4 +/- 0.3 at systole for TFE and 3.5 +/- 1.1 and 3.2 +/- 1.3 for SSFP, respectively (P < 0.0001). SSFP increases contrast between blood and myocardium more than twofold, resulting in an improved endocardial border definition. This may reduce variability for the determination of cardiac volumes and ejection fraction.

Why it matters

OpenAlex reports 217 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Contrast between blood and myocardium in standard turbo gradient echo MR techniques (TFE) used routinely in clinical practice is mainly caused by unsaturated inflowing blood. Steady-state free precession (SSFP) has excellent contrast even in the absence of inflow effects. In 45 subjects cardiac cine loops in two long axis projections were acquired using TFE and compared with SSFP. A visual score (range 0 worst - 3 best) was assigned for endocardial border delineation for six myocardial segments in two long axis views. Endocardial border delineation score for TFE was 1.3 +/- 0.3 per segment and 2.4 +/- 0.3 for SSFP (P < 0.0001). Signal intensity blood/signal intensity myocardium was 1.5 +/- 0.4 at enddiastole and 1.4 +/- 0.3 at systole for TFE and 3.5 +/- 1.1 and 3.2 +/- 1.3 for SSFP, respectively (P < 0.0001). SSFP increases contrast between blood and myocardium more than twofold, resulting in an improved endocardial border definition. This may reduce variability for the determination of cardiac volumes and ejection fraction.

Key concepts: Steady-state free precession imaging, Medicine, Contrast (vision), Precession, Nuclear medicine, Ejection fraction, Intensity (physics), Nuclear magnetic resonance