2004Equine Veterinary JournalRequires access

Measurement of respiratory function by impulse oscillometry in horses

Emmanuelle Van Erck, Dominique M. Votion, Tatiana Art, Pierre M. Lekeux

Open publisher page 48 citations

Abstract

REASONS FOR PERFORMING STUDY: Due to technical implementations and lack of sensitivity, pulmonary function tests are seldom used in clinical practice. Impulse oscillometry (IOS) could represent an alternative method. OBJECTIVES: To define feasibility, methodology and repeatability of IOS, a forced oscillation technique that measures respiratory resistance (Rrs) and reactance (Xrs) from 5 to 35 Hz during spontaneous breathing, in horses. METHODS: Using 38 healthy horses, Rrs and Xrs reference values were defined and influence of individual biometrical parameters was investigated. In addition, IOS measurements of 6 horses showing clinical signs of heaves were compared to those of 6 healthy horses. RESULTS: Airtightness and minimal dead space in the facemask were prerequisites to IOS testing and standardisation of head position was necessary to avoid variations in Rrs due to modified upper airway geometry. In both healthy and diseased animals, measurements were repeatable. In standard-type breeds, the influence of the horse's size on IOS parameters was negligible. An increase in R5Hz greater than 0.10 kPa/l/sec and R5Hz>R10Hz, combined with negative values of Xrs between 5 and 20 Hz, was indicative of heaves crisis. CONCLUSIONS: IOS is a quick, minimally invasive and informative method for pulmonary function testing in healthy and diseased horses. POTENTIAL RELEVANCE: IOS is a promising method for routine and/or field respiratory clinical testing in the equine species.

About this research paper

What this paper is about

REASONS FOR PERFORMING STUDY: Due to technical implementations and lack of sensitivity, pulmonary function tests are seldom used in clinical practice. Impulse oscillometry (IOS) could represent an alternative method. OBJECTIVES: To define feasibility, methodology and repeatability of IOS, a forced oscillation technique that measures respiratory resistance (Rrs) and reactance (Xrs) from 5 to 35 Hz during spontaneous breathing, in horses. METHODS: Using 38 healthy horses, Rrs and Xrs reference values were defined and influence of individual biometrical parameters was investigated. In addition, IOS measurements of 6 horses showing clinical signs of heaves were compared to those of 6 healthy horses. RESULTS: Airtightness and minimal dead space in the facemask were prerequisites to IOS testing and standardisation of head position was necessary to avoid variations in Rrs due to modified upper airway geometry. In both healthy and diseased animals, measurements were repeatable. In standard-type breeds, the influence of the horse's size on IOS parameters was negligible. An increase in R5Hz greater than 0.10 kPa/l/sec and R5Hz>R10Hz, combined with negative values of Xrs between 5 and 20 Hz, was indicative of heaves crisis. CONCLUSIONS: IOS is a quick, minimally invasive and informative method for pulmonary function testing in healthy and diseased horses. POTENTIAL RELEVANCE: IOS is a promising method for routine and/or field respiratory clinical testing in the equine species.

Why it matters

OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

REASONS FOR PERFORMING STUDY: Due to technical implementations and lack of sensitivity, pulmonary function tests are seldom used in clinical practice. Impulse oscillometry (IOS) could represent an alternative method. OBJECTIVES: To define feasibility, methodology and repeatability of IOS, a forced oscillation technique that measures respiratory resistance (Rrs) and reactance (Xrs) from 5 to 35 Hz during spontaneous breathing, in horses. METHODS: Using 38 healthy horses, Rrs and Xrs reference values were defined and influence of individual biometrical parameters was investigated. In addition, IOS measurements of 6 horses showing clinical signs of heaves were compared to those of 6 healthy horses. RESULTS: Airtightness and minimal dead space in the facemask were prerequisites to IOS testing and standardisation of head position was necessary to avoid variations in Rrs due to modified upper airway geometry. In both healthy and diseased animals, measurements were repeatable. In standard-type breeds, the influence of the horse's size on IOS parameters was negligible. An increase in R5Hz greater than 0.10 kPa/l/sec and R5Hz>R10Hz, combined with negative values of Xrs between 5 and 20 Hz, was indicative of heaves crisis. CONCLUSIONS: IOS is a quick, minimally invasive and informative method for pulmonary function testing in healthy and diseased horses. POTENTIAL RELEVANCE: IOS is a promising method for routine and/or field respiratory clinical testing in the equine species.

Key concepts: Repeatability, Medicine, Horse, Pulmonary function testing, Lung function, Airway resistance, Respiratory system, Forced oscillation

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of respiratory function by impulse oscillometry in horses — Research Paper | ScholarLens