2002American Journal of Physical Medicine & RehabilitationRequires access

Mechanical Insufflation-Exsufflation

Elia Gómez-Merino, Jesús Sancho, Julio Marín, Emilio Servera, María Luisa Blasco, F. J. Belda, Christopher Castro, John R. Bach

Open publisher page 100 citations

Abstract

OBJECTIVE: Pulmonary complications of neuromuscular disease can be averted by increasing peak cough flows with the use of a forced exsufflation device. The purpose of this study was to examine the pressure, volume, and flow relationships for a range of settings generated by this device, and compare them with clinically efficacious values and the manufacturer's guidelines. METHODS: The In-exsufflator was connected to a standard lung model. The resulting forced deflation volumes, flows, and pressures were averaged over 10 cycles at each setting. RESULTS: The set insufflation pressures significantly correlated with the generated insufflation pressures and volumes and the exsufflation volumes and flows. Increasing set insufflation time significantly increased generated insufflation pressures, flows, and volumes and exsufflation volumes. Increasing set exsufflation time did not significantly increase generated exsufflation flows. At set pressures of 40 to -40 cm H2O, insufflation time of 3 sec, and exsufflation time of 2 sec, the exsufflation flow was 4.09 l/sec. A plateau insufflation volume of 3.8 l was reached after 4.9 sec of insufflation. CONCLUSIONS: In-exsufflator performance was very consistent. Its clinical effectiveness can be explained by its generation of exsufflation flows >2.7 l/sec. Increasing insufflation times more than exsufflation times is more important for optimal function. Current manufacturer use guidelines may not yield optimal exsufflation flows.

About this research paper

What this paper is about

OBJECTIVE: Pulmonary complications of neuromuscular disease can be averted by increasing peak cough flows with the use of a forced exsufflation device. The purpose of this study was to examine the pressure, volume, and flow relationships for a range of settings generated by this device, and compare them with clinically efficacious values and the manufacturer's guidelines. METHODS: The In-exsufflator was connected to a standard lung model. The resulting forced deflation volumes, flows, and pressures were averaged over 10 cycles at each setting. RESULTS: The set insufflation pressures significantly correlated with the generated insufflation pressures and volumes and the exsufflation volumes and flows. Increasing set insufflation time significantly increased generated insufflation pressures, flows, and volumes and exsufflation volumes. Increasing set exsufflation time did not significantly increase generated exsufflation flows. At set pressures of 40 to -40 cm H2O, insufflation time of 3 sec, and exsufflation time of 2 sec, the exsufflation flow was 4.09 l/sec. A plateau insufflation volume of 3.8 l was reached after 4.9 sec of insufflation. CONCLUSIONS: In-exsufflator performance was very consistent. Its clinical effectiveness can be explained by its generation of exsufflation flows >2.7 l/sec. Increasing insufflation times more than exsufflation times is more important for optimal function. Current manufacturer use guidelines may not yield optimal exsufflation flows.

Why it matters

OpenAlex reports 100 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Pulmonary complications of neuromuscular disease can be averted by increasing peak cough flows with the use of a forced exsufflation device. The purpose of this study was to examine the pressure, volume, and flow relationships for a range of settings generated by this device, and compare them with clinically efficacious values and the manufacturer's guidelines. METHODS: The In-exsufflator was connected to a standard lung model. The resulting forced deflation volumes, flows, and pressures were averaged over 10 cycles at each setting. RESULTS: The set insufflation pressures significantly correlated with the generated insufflation pressures and volumes and the exsufflation volumes and flows. Increasing set insufflation time significantly increased generated insufflation pressures, flows, and volumes and exsufflation volumes. Increasing set exsufflation time did not significantly increase generated exsufflation flows. At set pressures of 40 to -40 cm H2O, insufflation time of 3 sec, and exsufflation time of 2 sec, the exsufflation flow was 4.09 l/sec. A plateau insufflation volume of 3.8 l was reached after 4.9 sec of insufflation. CONCLUSIONS: In-exsufflator performance was very consistent. Its clinical effectiveness can be explained by its generation of exsufflation flows >2.7 l/sec. Increasing insufflation times more than exsufflation times is more important for optimal function. Current manufacturer use guidelines may not yield optimal exsufflation flows.

Key concepts: Exsufflation, Insufflation, Medicine, Anesthesia, Volume (thermodynamics), Thermodynamics, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Mechanical Insufflation-Exsufflation — Research Paper | ScholarLens