1995Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Evaluation of the radiation characteristics of a high-temperature blackbody

Benjamin K. Tsai, Bettye C. Johnson, Robert D. Saunders

Open publisher page 3 citations

Abstract

Development of a new spectral irradiance scale realization at the National Institute of Standards and Technology (NIST) requires a careful and complete calibration of a high- temperature blackbody between 1200 K and 2800 K. Filter radiometers have been calibrated to measure the spectral radiance (or radiance temperature) of the blackbody. Using a monochromator, the blackbody spectral radiance will then be used to determine the spectral irradiance distributions of primary and secondary spectral irradiance lamp standards at NIST. In this paper, a calibrated pyrometer and V((lambda) ) filter radiometer will be used to evaluate the high-temperature blackbody for determination of the optimum calibration method for the blackbody. The blackbody apparatus will be described in detail. When the power supply is the sole source of current control, the blackbody current is stable to within 0.056%, resulting in 0.72% for the uncertainty in the blackbody spectral radiance. To achieve our goal of 0.1% in the final blackbody radiance, a blackbody current stability of 0.007% is required. Due to the day-to-day variations in the current, calibrations of the blackbody msut be made frequently. Several feedback control options are recommended as possible solutions for improving both the short term and long term current stability.

About this research paper

What this paper is about

Development of a new spectral irradiance scale realization at the National Institute of Standards and Technology (NIST) requires a careful and complete calibration of a high- temperature blackbody between 1200 K and 2800 K. Filter radiometers have been calibrated to measure the spectral radiance (or radiance temperature) of the blackbody. Using a monochromator, the blackbody spectral radiance will then be used to determine the spectral irradiance distributions of primary and secondary spectral irradiance lamp standards at NIST. In this paper, a calibrated pyrometer and V((lambda) ) filter radiometer will be used to evaluate the high-temperature blackbody for determination of the optimum calibration method for the blackbody. The blackbody apparatus will be described in detail. When the power supply is the sole source of current control, the blackbody current is stable to within 0.056%, resulting in 0.72% for the uncertainty in the blackbody spectral radiance. To achieve our goal of 0.1% in the final blackbody radiance, a blackbody current stability of 0.007% is required. Due to the day-to-day variations in the current, calibrations of the blackbody msut be made frequently. Several feedback control options are recommended as possible solutions for improving both the short term and long term current stability.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Development of a new spectral irradiance scale realization at the National Institute of Standards and Technology (NIST) requires a careful and complete calibration of a high- temperature blackbody between 1200 K and 2800 K. Filter radiometers have been calibrated to measure the spectral radiance (or radiance temperature) of the blackbody. Using a monochromator, the blackbody spectral radiance will then be used to determine the spectral irradiance distributions of primary and secondary spectral irradiance lamp standards at NIST. In this paper, a calibrated pyrometer and V((lambda) ) filter radiometer will be used to evaluate the high-temperature blackbody for determination of the optimum calibration method for the blackbody. The blackbody apparatus will be described in detail. When the power supply is the sole source of current control, the blackbody current is stable to within 0.056%, resulting in 0.72% for the uncertainty in the blackbody spectral radiance. To achieve our goal of 0.1% in the final blackbody radiance, a blackbody current stability of 0.007% is required. Due to the day-to-day variations in the current, calibrations of the blackbody msut be made frequently. Several feedback control options are recommended as possible solutions for improving both the short term and long term current stability.

Key concepts: Radiance, Black-body radiation, Radiometer, NIST, Physics, Irradiance, Calibration, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of the radiation characteristics of a high-temperature blackbody — Research Paper | ScholarLens