2010Journal of GlaucomaRequires access

Comparison of Retinal Nerve Fiber Layer Thickness Measurements Using Time Domain and Spectral Domain Optical Coherence Tomography, and Visual Field Sensitivity

Mai Takagishi, Kazuyuki Hirooka, Tetsuya Baba, Masanori Mizote, Fumio Shiraga

Open publisher page 38 citations

Abstract

PURPOSE: To investigate the relationship between the peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by Stratus time domain optical coherence tomography (OCT) (Stratus OCT) and Cirrus spectral domain OCT (Cirrus HD-OCT), and the severity indices of the visual field (VF) defects in glaucoma patients. METHODS: This was a prospective, cross-sectional study. Correlations between the individual VF sensitivity at 52 test points and the Stratus OCT and Cirrus HD-OCT, which determined peripapillary RNFL thicknesses from 6 sectors, were calculated in 54 eyes with open-angle glaucoma and 22 normal control eyes. The association between the RNFL thickness and VF sensitivity was evaluated using a second-order regression model. RESULTS: A significant correlation was found for the RNFL thicknesses determined by the 2 OCT devices (r=0.51 to 0.95; P<0.001). VF sensitivities at each test point were also significantly correlated with the sectoral RNFL thicknesses. The inferotemporal RNFL sector exhibited the highest coefficient of determination, whereas the superotemporal test point had the highest VF sensitivity (Stratus, 0.70; Cirrus, 0.62). CONCLUSIONS: The structure-function relationship was comparable between Cirrus HD-OCT and Stratus OCT RNFL measurements.

About this research paper

What this paper is about

PURPOSE: To investigate the relationship between the peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by Stratus time domain optical coherence tomography (OCT) (Stratus OCT) and Cirrus spectral domain OCT (Cirrus HD-OCT), and the severity indices of the visual field (VF) defects in glaucoma patients. METHODS: This was a prospective, cross-sectional study. Correlations between the individual VF sensitivity at 52 test points and the Stratus OCT and Cirrus HD-OCT, which determined peripapillary RNFL thicknesses from 6 sectors, were calculated in 54 eyes with open-angle glaucoma and 22 normal control eyes. The association between the RNFL thickness and VF sensitivity was evaluated using a second-order regression model. RESULTS: A significant correlation was found for the RNFL thicknesses determined by the 2 OCT devices (r=0.51 to 0.95; P<0.001). VF sensitivities at each test point were also significantly correlated with the sectoral RNFL thicknesses. The inferotemporal RNFL sector exhibited the highest coefficient of determination, whereas the superotemporal test point had the highest VF sensitivity (Stratus, 0.70; Cirrus, 0.62). CONCLUSIONS: The structure-function relationship was comparable between Cirrus HD-OCT and Stratus OCT RNFL measurements.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate the relationship between the peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by Stratus time domain optical coherence tomography (OCT) (Stratus OCT) and Cirrus spectral domain OCT (Cirrus HD-OCT), and the severity indices of the visual field (VF) defects in glaucoma patients. METHODS: This was a prospective, cross-sectional study. Correlations between the individual VF sensitivity at 52 test points and the Stratus OCT and Cirrus HD-OCT, which determined peripapillary RNFL thicknesses from 6 sectors, were calculated in 54 eyes with open-angle glaucoma and 22 normal control eyes. The association between the RNFL thickness and VF sensitivity was evaluated using a second-order regression model. RESULTS: A significant correlation was found for the RNFL thicknesses determined by the 2 OCT devices (r=0.51 to 0.95; P<0.001). VF sensitivities at each test point were also significantly correlated with the sectoral RNFL thicknesses. The inferotemporal RNFL sector exhibited the highest coefficient of determination, whereas the superotemporal test point had the highest VF sensitivity (Stratus, 0.70; Cirrus, 0.62). CONCLUSIONS: The structure-function relationship was comparable between Cirrus HD-OCT and Stratus OCT RNFL measurements.

Key concepts: Cirrus, Optical coherence tomography, Nerve fiber layer, Glaucoma, Ophthalmology, Medicine, Visual field, Retinal

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Retinal Nerve Fiber Layer Thickness Measurements Using Time Domain and Spectral Domain Optical Coherence Tomography, and Visual Field Sensitivity — Research Paper | ScholarLens