The characteristics of the detector prototype for 1–15 MeV neutrons are described. The prototype is a full absorption detector consisting of interlaced plastic scintillators and 6 Li doped glasses. A neutron incident on the detector deposits all its energy in the plastic scintillator, is moderated to thermal energies, and detected in the lithium glass. The measured time of complete neutron moderation is ∼60 μs. Recording two signals in this time interval from the first event of neutron scattering in the plastic scintillator and from the neutron absorption by a lithium atom in the glass, it is possible to effectively suppress background thermal neutrons and γ rays and, therefore, detect low-intensity neutron sources. Owing to the proposed detector design, the direction toward the neutron source can be determined.

About this research paper

What this paper is about

The characteristics of the detector prototype for 1–15 MeV neutrons are described. The prototype is a full absorption detector consisting of interlaced plastic scintillators and 6 Li doped glasses. A neutron incident on the detector deposits all its energy in the plastic scintillator, is moderated to thermal energies, and detected in the lithium glass. The measured time of complete neutron moderation is ∼60 μs. Recording two signals in this time interval from the first event of neutron scattering in the plastic scintillator and from the neutron absorption by a lithium atom in the glass, it is possible to effectively suppress background thermal neutrons and γ rays and, therefore, detect low-intensity neutron sources. Owing to the proposed detector design, the direction toward the neutron source can be determined.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The characteristics of the detector prototype for 1–15 MeV neutrons are described. The prototype is a full absorption detector consisting of interlaced plastic scintillators and 6 Li doped glasses. A neutron incident on the detector deposits all its energy in the plastic scintillator, is moderated to thermal energies, and detected in the lithium glass. The measured time of complete neutron moderation is ∼60 μs. Recording two signals in this time interval from the first event of neutron scattering in the plastic scintillator and from the neutron absorption by a lithium atom in the glass, it is possible to effectively suppress background thermal neutrons and γ rays and, therefore, detect low-intensity neutron sources. Owing to the proposed detector design, the direction toward the neutron source can be determined.

Key concepts: Scintillator, Neutron, Neutron detection, Neutron temperature, Detector, Nuclear physics, Bonner sphere, Scintillation

Related papers

Back to paper searchBrowse research topicsOriginal source
A method for measuring the energy spectrum of neutrons with energies of 1–15 MeV — Research Paper | ScholarLens