1989Journal of Atmospheric and Oceanic TechnologyRequires access

An Instantaneous CCN Spectrometer

James G. Hudson

Open publisher page 137 citations

Abstract

A thermal gradient diffusion cloud chamber with a supersaturation field that increases along the path of the flow of sample is used as a cloud condensation nucleus (CCN) spectrometer. The CCN spectrum is derived from the final droplet size distribution which has been determined to be related to the nucleus critical super-saturation based on routine calibration procedures using laboratory-produced monodisperse salt particles. The instrument is compared against a previously reported CCN counter on natural and laboratory-produced aerosol and against an absolute CN counter on the monodisperse aerosol. Preliminary results of atmospheric measurements are given. This device produces a CCN spectrum over the entire useful range of interest for cloud physics (0.01% to 1% supersaturation). More than 40 channels of resolution over this range are simultaneously provided. Data can be collected on a continuous basis for integration times as short as 2 seconds. The instrument has obtained data from four different airborne platforms as well as from a mobile surface platform. The number of channels allows the CCN spectrum to be displayed differentially instead of the usual cumulative display traditionally used in cloud physics.

About this research paper

What this paper is about

A thermal gradient diffusion cloud chamber with a supersaturation field that increases along the path of the flow of sample is used as a cloud condensation nucleus (CCN) spectrometer. The CCN spectrum is derived from the final droplet size distribution which has been determined to be related to the nucleus critical super-saturation based on routine calibration procedures using laboratory-produced monodisperse salt particles. The instrument is compared against a previously reported CCN counter on natural and laboratory-produced aerosol and against an absolute CN counter on the monodisperse aerosol. Preliminary results of atmospheric measurements are given. This device produces a CCN spectrum over the entire useful range of interest for cloud physics (0.01% to 1% supersaturation). More than 40 channels of resolution over this range are simultaneously provided. Data can be collected on a continuous basis for integration times as short as 2 seconds. The instrument has obtained data from four different airborne platforms as well as from a mobile surface platform. The number of channels allows the CCN spectrum to be displayed differentially instead of the usual cumulative display traditionally used in cloud physics.

Why it matters

OpenAlex reports 137 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A thermal gradient diffusion cloud chamber with a supersaturation field that increases along the path of the flow of sample is used as a cloud condensation nucleus (CCN) spectrometer. The CCN spectrum is derived from the final droplet size distribution which has been determined to be related to the nucleus critical super-saturation based on routine calibration procedures using laboratory-produced monodisperse salt particles. The instrument is compared against a previously reported CCN counter on natural and laboratory-produced aerosol and against an absolute CN counter on the monodisperse aerosol. Preliminary results of atmospheric measurements are given. This device produces a CCN spectrum over the entire useful range of interest for cloud physics (0.01% to 1% supersaturation). More than 40 channels of resolution over this range are simultaneously provided. Data can be collected on a continuous basis for integration times as short as 2 seconds. The instrument has obtained data from four different airborne platforms as well as from a mobile surface platform. The number of channels allows the CCN spectrum to be displayed differentially instead of the usual cumulative display traditionally used in cloud physics.

Key concepts: Cloud condensation nuclei, Aerosol, Supersaturation, Spectrometer, Dispersity, Computational physics, Physics, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
An Instantaneous CCN Spectrometer — Research Paper | ScholarLens