2007StrokeOpen access

Enhanced Detection of Thromboemboli With the Use of Targeted Microbubbles

Matthew Martin, Emma M.L. Chung, Alison H. Goodall, Alberto Della Martina, Kumar V. Ramnarine, Lingke Fan, S. V. Hainsworth, A. Ross Naylor, David H. Evans

Open full text 33 citations

Abstract

BACKGROUND AND PURPOSE: Targeted ultrasound contrast agents have recently been developed to adhere selectively to specific pathogenic materials such as plaque or thrombus. Administration of such microbubbles has potential to aid transcranial Doppler ultrasound (TCD) detection of emboli and to act as markers for distinguishing one embolic material from another. The purpose of this study was to investigate whether TCD detection of circulating thrombus emboli would be enhanced by the addition of targeted microbubbles. METHODS: Binding of microbubbles to the surface of the thrombus was confirmed by scanning electron microscopy. Targeted and control bubbles were then introduced to thrombus and tissue-mimicking material circulated under pulsatile-flow conditions in an in vitro flow rig. Embolic signal intensities before and after introduction of the bubbles were measured by TCD. RESULTS: Targeted microbubbles enhanced TCD signal intensities from thrombus emboli by up to 13 dB. The bubbles were capable of binding to moving thrombus when injected into the flow circuit in low concentrations ( approximately 36 bubbles per 100 mL) and were retained on the thrombus under pulsatile-flow conditions. Signal intensities from similarly sized pieces of tissue-mimicking material were not enhanced by injection of targeted bubbles. CONCLUSIONS: Injection of appropriately targeted microbubbles significantly enhances TCD detection of circulating thrombus emboli in vitro.

Open-access reader

About this research paper

What this paper is about

BACKGROUND AND PURPOSE: Targeted ultrasound contrast agents have recently been developed to adhere selectively to specific pathogenic materials such as plaque or thrombus. Administration of such microbubbles has potential to aid transcranial Doppler ultrasound (TCD) detection of emboli and to act as markers for distinguishing one embolic material from another. The purpose of this study was to investigate whether TCD detection of circulating thrombus emboli would be enhanced by the addition of targeted microbubbles. METHODS: Binding of microbubbles to the surface of the thrombus was confirmed by scanning electron microscopy. Targeted and control bubbles were then introduced to thrombus and tissue-mimicking material circulated under pulsatile-flow conditions in an in vitro flow rig. Embolic signal intensities before and after introduction of the bubbles were measured by TCD. RESULTS: Targeted microbubbles enhanced TCD signal intensities from thrombus emboli by up to 13 dB. The bubbles were capable of binding to moving thrombus when injected into the flow circuit in low concentrations ( approximately 36 bubbles per 100 mL) and were retained on the thrombus under pulsatile-flow conditions. Signal intensities from similarly sized pieces of tissue-mimicking material were not enhanced by injection of targeted bubbles. CONCLUSIONS: Injection of appropriately targeted microbubbles significantly enhances TCD detection of circulating thrombus emboli in vitro.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND PURPOSE: Targeted ultrasound contrast agents have recently been developed to adhere selectively to specific pathogenic materials such as plaque or thrombus. Administration of such microbubbles has potential to aid transcranial Doppler ultrasound (TCD) detection of emboli and to act as markers for distinguishing one embolic material from another. The purpose of this study was to investigate whether TCD detection of circulating thrombus emboli would be enhanced by the addition of targeted microbubbles. METHODS: Binding of microbubbles to the surface of the thrombus was confirmed by scanning electron microscopy. Targeted and control bubbles were then introduced to thrombus and tissue-mimicking material circulated under pulsatile-flow conditions in an in vitro flow rig. Embolic signal intensities before and after introduction of the bubbles were measured by TCD. RESULTS: Targeted microbubbles enhanced TCD signal intensities from thrombus emboli by up to 13 dB. The bubbles were capable of binding to moving thrombus when injected into the flow circuit in low concentrations ( approximately 36 bubbles per 100 mL) and were retained on the thrombus under pulsatile-flow conditions. Signal intensities from similarly sized pieces of tissue-mimicking material were not enhanced by injection of targeted bubbles. CONCLUSIONS: Injection of appropriately targeted microbubbles significantly enhances TCD detection of circulating thrombus emboli in vitro.

Key concepts: Microbubbles, Thrombus, Medicine, Pulsatile flow, Transcranial Doppler, Ultrasound, Biomedical engineering, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Enhanced Detection of Thromboemboli With the Use of Targeted Microbubbles — Research Paper | ScholarLens