2014Analytical LettersRequires access

Determination of Brassinolide Analogs by High-Performance Liquid Chromatography with Evaporative Light Scattering Detection

Lidong Cao, Jing Yang, Xiuhuan Li, Dongwei Wang, Qiliang Huang

Open publisher page 2 citations

Abstract

An efficient method based on high-performance liquid chromatography with evaporative light scattering detection was developed for the separation and determination of four brassinolide analogs [24-epibrassinolide, (22S, 23S)-24-epibrassinolide, 28-homobrassinolide, and (22S, 23S)-28-epihomobrassinolide] without prior derivatization. The optimized analysis was carried out on a C18 reversed-phase column (150 mm × 4.60 mm, 3 µm) at 30°C using isocratic elution of acetonitrile and water (38:62, v/v). The drift tube temperature of the detector was 60°C and the auxiliary gas (nitrogen) pressure was 360 kPa. The regression equations revealed linear relationships (R2 = 0.9984–0.9994) within the test ranges. The limits of detection and quantification were in the ranges of 0.12 to 0.17 µg and 0.24 to 0.33 µg, respectively. The fully validated method was applied to quantify the active ingredient content in technical material and formulations and provides an alternative approach for quality control.

About this research paper

What this paper is about

An efficient method based on high-performance liquid chromatography with evaporative light scattering detection was developed for the separation and determination of four brassinolide analogs [24-epibrassinolide, (22S, 23S)-24-epibrassinolide, 28-homobrassinolide, and (22S, 23S)-28-epihomobrassinolide] without prior derivatization. The optimized analysis was carried out on a C18 reversed-phase column (150 mm × 4.60 mm, 3 µm) at 30°C using isocratic elution of acetonitrile and water (38:62, v/v). The drift tube temperature of the detector was 60°C and the auxiliary gas (nitrogen) pressure was 360 kPa. The regression equations revealed linear relationships (R2 = 0.9984–0.9994) within the test ranges. The limits of detection and quantification were in the ranges of 0.12 to 0.17 µg and 0.24 to 0.33 µg, respectively. The fully validated method was applied to quantify the active ingredient content in technical material and formulations and provides an alternative approach for quality control.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An efficient method based on high-performance liquid chromatography with evaporative light scattering detection was developed for the separation and determination of four brassinolide analogs [24-epibrassinolide, (22S, 23S)-24-epibrassinolide, 28-homobrassinolide, and (22S, 23S)-28-epihomobrassinolide] without prior derivatization. The optimized analysis was carried out on a C18 reversed-phase column (150 mm × 4.60 mm, 3 µm) at 30°C using isocratic elution of acetonitrile and water (38:62, v/v). The drift tube temperature of the detector was 60°C and the auxiliary gas (nitrogen) pressure was 360 kPa. The regression equations revealed linear relationships (R2 = 0.9984–0.9994) within the test ranges. The limits of detection and quantification were in the ranges of 0.12 to 0.17 µg and 0.24 to 0.33 µg, respectively. The fully validated method was applied to quantify the active ingredient content in technical material and formulations and provides an alternative approach for quality control.

Key concepts: Chemistry, Chromatography, Chromatography detector, High-performance liquid chromatography, Derivatization, Brassinolide, Elution, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Brassinolide Analogs by High-Performance Liquid Chromatography with Evaporative Light Scattering Detection — Research Paper | ScholarLens