1965The Journal of Chemical PhysicsRequires access

Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient

E. O. Stejskal, J. E. Tanner

Open publisher page 8,294 citations

Abstract

A derivation is given of the effect of a time-dependent magnetic field gradient on the spin-echo experiment, particularly in the presence of spin diffusion. There are several reasons for preferring certain kinds of time-dependent magnetic field gradients to the more usual steady gradient. If the gradient is reduced during the rf pulses, H1 need not be particularly large; if the gradient is small at the time of the echo, the echo will be broad and its amplitude easy to measure. Both of these relaxations of restrictions on the measurement of diffusion coefficients by the spin-echo technique serve to extend its range of applicability. Furthermore, a pulsed gradient can be recommended when it is critical to define the precise time period over which diffusion is being measured. The theoretical expression derived has been verified experimentally for several choices of time dependent magnetic field gradient. An apparatus is described suitable for the production of pulsed gradients with amplitudes as large as 100 G cm−1. The diffusion coefficient of dry glycerol at 26°±1°C has been found to be (2.5±0.2)×10−8 cm2 sec−1, a value smaller than can ordinarily be measured by the steady gradient method.

About this research paper

What this paper is about

A derivation is given of the effect of a time-dependent magnetic field gradient on the spin-echo experiment, particularly in the presence of spin diffusion. There are several reasons for preferring certain kinds of time-dependent magnetic field gradients to the more usual steady gradient. If the gradient is reduced during the rf pulses, H1 need not be particularly large; if the gradient is small at the time of the echo, the echo will be broad and its amplitude easy to measure. Both of these relaxations of restrictions on the measurement of diffusion coefficients by the spin-echo technique serve to extend its range of applicability. Furthermore, a pulsed gradient can be recommended when it is critical to define the precise time period over which diffusion is being measured. The theoretical expression derived has been verified experimentally for several choices of time dependent magnetic field gradient. An apparatus is described suitable for the production of pulsed gradients with amplitudes as large as 100 G cm−1. The diffusion coefficient of dry glycerol at 26°±1°C has been found to be (2.5±0.2)×10−8 cm2 sec−1, a value smaller than can ordinarily be measured by the steady gradient method.

Why it matters

OpenAlex reports 8294 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A derivation is given of the effect of a time-dependent magnetic field gradient on the spin-echo experiment, particularly in the presence of spin diffusion. There are several reasons for preferring certain kinds of time-dependent magnetic field gradients to the more usual steady gradient. If the gradient is reduced during the rf pulses, H1 need not be particularly large; if the gradient is small at the time of the echo, the echo will be broad and its amplitude easy to measure. Both of these relaxations of restrictions on the measurement of diffusion coefficients by the spin-echo technique serve to extend its range of applicability. Furthermore, a pulsed gradient can be recommended when it is critical to define the precise time period over which diffusion is being measured. The theoretical expression derived has been verified experimentally for several choices of time dependent magnetic field gradient. An apparatus is described suitable for the production of pulsed gradients with amplitudes as large as 100 G cm−1. The diffusion coefficient of dry glycerol at 26°±1°C has been found to be (2.5±0.2)×10−8 cm2 sec−1, a value smaller than can ordinarily be measured by the steady gradient method.

Key concepts: Diffusion, Pulsed field gradient, Spin echo, Amplitude, Temperature gradient, Nuclear magnetic resonance, Field (mathematics), Spin (aerodynamics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient — Research Paper | ScholarLens