Experimental evaluation of new concepts in hip arthroplasty

Tina S Wik

Open full text 18 citations

Abstract

In this thesis we evaluated two different hip arthroplasty concepts trough in vitro studies and numerical analyses. The cortical strains in the femoral neck area were increased by 10 to 15 % after insertion of a resurfacing femoral component compared to values of the intact femur, shown in an in vitro study on human cadaver femurs. There is an increased risk of femoral neck fracture after hip resurfacing arthroplasty. An increase of 10 to 15 % in femoral neck strains is limited, and cannot alone explain these fractures. Together with patient specific and surgical factors, however, increased strain can contribute to increased risk of fracture. An in vitro study showed that increasing the neck length in combination with retroversion or reduced neck shaft angle on a standard cementless femoral stem does not compromise the stability of the stem. The strain pattern in the proximal femur increased significantly at several measuring sites when the version and length of neck were altered. However, the changes were probably too small to have clinical relevance. In a validation study we have shown that a subject specific finite element analysis is able to perform reasonable predictions of strains and stress shielding after insertion of a femoral stem in human cadaver femurs. The usage of finite element models can be a valuable supplement to in vitro tests of femoral strain pattern around hip arthroplasty. Finally, a patient case shows that bone resorption around an implant caused by stress shielding can in extreme cases lead to periprosthetic fracture.

Open-access reader

About this research paper

What this paper is about

In this thesis we evaluated two different hip arthroplasty concepts trough in vitro studies and numerical analyses. The cortical strains in the femoral neck area were increased by 10 to 15 % after insertion of a resurfacing femoral component compared to values of the intact femur, shown in an in vitro study on human cadaver femurs. There is an increased risk of femoral neck fracture after hip resurfacing arthroplasty. An increase of 10 to 15 % in femoral neck strains is limited, and cannot alone explain these fractures. Together with patient specific and surgical factors, however, increased strain can contribute to increased risk of fracture. An in vitro study showed that increasing the neck length in combination with retroversion or reduced neck shaft angle on a standard cementless femoral stem does not compromise the stability of the stem. The strain pattern in the proximal femur increased significantly at several measuring sites when the version and length of neck were altered. However, the changes were probably too small to have clinical relevance. In a validation study we have shown that a subject specific finite element analysis is able to perform reasonable predictions of strains and stress shielding after insertion of a femoral stem in human cadaver femurs. The usage of finite element models can be a valuable supplement to in vitro tests of femoral strain pattern around hip arthroplasty. Finally, a patient case shows that bone resorption around an implant caused by stress shielding can in extreme cases lead to periprosthetic fracture.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this thesis we evaluated two different hip arthroplasty concepts trough in vitro studies and numerical analyses. The cortical strains in the femoral neck area were increased by 10 to 15 % after insertion of a resurfacing femoral component compared to values of the intact femur, shown in an in vitro study on human cadaver femurs. There is an increased risk of femoral neck fracture after hip resurfacing arthroplasty. An increase of 10 to 15 % in femoral neck strains is limited, and cannot alone explain these fractures. Together with patient specific and surgical factors, however, increased strain can contribute to increased risk of fracture. An in vitro study showed that increasing the neck length in combination with retroversion or reduced neck shaft angle on a standard cementless femoral stem does not compromise the stability of the stem. The strain pattern in the proximal femur increased significantly at several measuring sites when the version and length of neck were altered. However, the changes were probably too small to have clinical relevance. In a validation study we have shown that a subject specific finite element analysis is able to perform reasonable predictions of strains and stress shielding after insertion of a femoral stem in human cadaver femurs. The usage of finite element models can be a valuable supplement to in vitro tests of femoral strain pattern around hip arthroplasty. Finally, a patient case shows that bone resorption around an implant caused by stress shielding can in extreme cases lead to periprosthetic fracture.

Key concepts: Periprosthetic, Stress shielding, Medicine, Femoral neck, Femur, Cadaver, Arthroplasty, Biomechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental evaluation of new concepts in hip arthroplasty — Research Paper | ScholarLens