2013•Clinical and Experimental HypertensionRequires access

Clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring

Yasuo Kansui, Kiyoshi Matsumura, Haruko Kida, Satoko Sakata, Toshio Ohtsubo, Ai Ibaraki, Takanari Kitazono

Open publisher page 7 citations

Abstract

Strict control of blood pressure is important to prevent cardiovascular disease, although it is sometimes difficult to decrease blood pressure to target levels. The aim of this study was to investigate the clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring. One hundred in-hospital patients, whose 24-hour average blood pressure was higher than 130/80 mmHg even after treatment with more than three antihypertensive drugs, were included in the present analysis. Circadian variation of blood pressure was evaluated by nocturnal fall in systolic blood pressure. Average blood pressures of all patients were high in both daytime and nighttime, 150.0/82.9 and 143.8/78.2 mmHg, respectively. Twenty patients had been treated with hemodialysis or peritoneal dialysis. In 63 patients out of the other 80 patients (79%), estimated glomerular filtration rate (eGFR) was also decreased (<60 mL/min/1.73 m²). The patients classified into dipper, non-dipper, riser and extreme-dipper were 20%, 43%, 34% and 3%, respectively. In addition, in 17 patients whose eGFR was preserved, 12 patients showed a non-dipper or riser pattern, suggesting that it was difficult to account for this altered circadian blood pressure variation only by renal dysfunction. These results show that a large number of the patients with resistant hypertension suffered from renal dysfunction, although it was difficult to explain altered circadian blood pressure variation based on renal dysfunction alone.

About this research paper

What this paper is about

Strict control of blood pressure is important to prevent cardiovascular disease, although it is sometimes difficult to decrease blood pressure to target levels. The aim of this study was to investigate the clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring. One hundred in-hospital patients, whose 24-hour average blood pressure was higher than 130/80 mmHg even after treatment with more than three antihypertensive drugs, were included in the present analysis. Circadian variation of blood pressure was evaluated by nocturnal fall in systolic blood pressure. Average blood pressures of all patients were high in both daytime and nighttime, 150.0/82.9 and 143.8/78.2 mmHg, respectively. Twenty patients had been treated with hemodialysis or peritoneal dialysis. In 63 patients out of the other 80 patients (79%), estimated glomerular filtration rate (eGFR) was also decreased (<60 mL/min/1.73 m²). The patients classified into dipper, non-dipper, riser and extreme-dipper were 20%, 43%, 34% and 3%, respectively. In addition, in 17 patients whose eGFR was preserved, 12 patients showed a non-dipper or riser pattern, suggesting that it was difficult to account for this altered circadian blood pressure variation only by renal dysfunction. These results show that a large number of the patients with resistant hypertension suffered from renal dysfunction, although it was difficult to explain altered circadian blood pressure variation based on renal dysfunction alone.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Strict control of blood pressure is important to prevent cardiovascular disease, although it is sometimes difficult to decrease blood pressure to target levels. The aim of this study was to investigate the clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring. One hundred in-hospital patients, whose 24-hour average blood pressure was higher than 130/80 mmHg even after treatment with more than three antihypertensive drugs, were included in the present analysis. Circadian variation of blood pressure was evaluated by nocturnal fall in systolic blood pressure. Average blood pressures of all patients were high in both daytime and nighttime, 150.0/82.9 and 143.8/78.2 mmHg, respectively. Twenty patients had been treated with hemodialysis or peritoneal dialysis. In 63 patients out of the other 80 patients (79%), estimated glomerular filtration rate (eGFR) was also decreased (<60 mL/min/1.73 m²). The patients classified into dipper, non-dipper, riser and extreme-dipper were 20%, 43%, 34% and 3%, respectively. In addition, in 17 patients whose eGFR was preserved, 12 patients showed a non-dipper or riser pattern, suggesting that it was difficult to account for this altered circadian blood pressure variation only by renal dysfunction. These results show that a large number of the patients with resistant hypertension suffered from renal dysfunction, although it was difficult to explain altered circadian blood pressure variation based on renal dysfunction alone.

Key concepts: Dipper, Medicine, Blood pressure, Ambulatory blood pressure, Circadian rhythm, Cardiology, Internal medicine, Hemodialysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical characteristics of resistant hypertension evaluated by ambulatory blood pressure monitoring — Research Paper | ScholarLens