1979Journal of Clinical PathologyOpen access

Comparison of passive haemagglutination and haemagglutination-inhibition techniques for detection of antibodies to rubella virus.

Chris Birch, Braeme Glaun, Valerie A. Hunt, Louise G. Irving, I. D. Gust

Open full text 14 citations

Abstract

Because of the technical problems and length of time involved in the satisfactory performance of the haemagglutination-inhibition test for detection of rubella-specific antibodies, a commercially available passive haemagglutination (PHA) kit utilising rubella antigen-sensitised human erythrocytes was tested for its suitability for use in diagnostic laboratories. The immune response to acute rubella infections as measured by PHA was considerably delayed compared to the response measured by haemagglutination-inhitition. Titres of rubella-specific antibody only became comparable six months after the infection. The commercially available PHA kits is a useful addition to diagnostic laboratories for the determination of immune status and, in conjunction with the haemagglutination-inhibition test, can be an indicator of recent rubella infection.

Open-access reader

About this research paper

What this paper is about

Because of the technical problems and length of time involved in the satisfactory performance of the haemagglutination-inhibition test for detection of rubella-specific antibodies, a commercially available passive haemagglutination (PHA) kit utilising rubella antigen-sensitised human erythrocytes was tested for its suitability for use in diagnostic laboratories. The immune response to acute rubella infections as measured by PHA was considerably delayed compared to the response measured by haemagglutination-inhitition. Titres of rubella-specific antibody only became comparable six months after the infection. The commercially available PHA kits is a useful addition to diagnostic laboratories for the determination of immune status and, in conjunction with the haemagglutination-inhibition test, can be an indicator of recent rubella infection.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Because of the technical problems and length of time involved in the satisfactory performance of the haemagglutination-inhibition test for detection of rubella-specific antibodies, a commercially available passive haemagglutination (PHA) kit utilising rubella antigen-sensitised human erythrocytes was tested for its suitability for use in diagnostic laboratories. The immune response to acute rubella infections as measured by PHA was considerably delayed compared to the response measured by haemagglutination-inhitition. Titres of rubella-specific antibody only became comparable six months after the infection. The commercially available PHA kits is a useful addition to diagnostic laboratories for the determination of immune status and, in conjunction with the haemagglutination-inhibition test, can be an indicator of recent rubella infection.

Key concepts: Hemagglutination, Rubella, Haemagglutination inhibition, Rubella virus, Virology, Antibody, Immunology, Immune system

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of passive haemagglutination and haemagglutination-inhibition techniques for detection of antibodies to rubella virus. — Research Paper | ScholarLens