1989Journal of Geophysical Research AtmospheresRequires access

Diurnal variations of mesospheric ozone obtained by ground‐based microwave radiometry

W. C. Zommerfelds, K. Künzi, M. E. Summers, R. M. Bevilacqua, Darrell F. Strobel, Mark Allen, W. J. Sawchuck

Open publisher page 75 citations

Abstract

From December 1986 until April 1987 ground‐based microwave observations of the diurnal variation of mesospheric ozone were made over Bern, Switzerland. These data were of sufficient quality to define the characteristic diurnal behavior of the ozone mixing ratio during winter and equinoctial conditions. The observed diurnal variation of ozone peaks at ∼74 km, where its amplitude is about a factor of 6. At 65 km the observed diurnal variation is a factor of 3, whereas at 55 km it is only a factor of 1.4. One‐dimensional model calculations accurately reproduce the relative diurnal variation of ozone at equinox, suggesting that the model value of the ozone photolysis rate coefficient is accurate to better than 10%. For winter conditions, however, the model underpredicts the observed relative diurnal variation by a factor of 2; a major part of this discrepancy is due to an observed postmidnight increase in ozone. Various suggested changes in model parameters to better reproduce the ozone abundance vertical profile result in only small differences in the relative diurnal variation, indicating that these observations do not provide a sensitive test of the mesopheric chemistry controlling the abundance of odd oxygen.

About this research paper

What this paper is about

From December 1986 until April 1987 ground‐based microwave observations of the diurnal variation of mesospheric ozone were made over Bern, Switzerland. These data were of sufficient quality to define the characteristic diurnal behavior of the ozone mixing ratio during winter and equinoctial conditions. The observed diurnal variation of ozone peaks at ∼74 km, where its amplitude is about a factor of 6. At 65 km the observed diurnal variation is a factor of 3, whereas at 55 km it is only a factor of 1.4. One‐dimensional model calculations accurately reproduce the relative diurnal variation of ozone at equinox, suggesting that the model value of the ozone photolysis rate coefficient is accurate to better than 10%. For winter conditions, however, the model underpredicts the observed relative diurnal variation by a factor of 2; a major part of this discrepancy is due to an observed postmidnight increase in ozone. Various suggested changes in model parameters to better reproduce the ozone abundance vertical profile result in only small differences in the relative diurnal variation, indicating that these observations do not provide a sensitive test of the mesopheric chemistry controlling the abundance of odd oxygen.

Why it matters

OpenAlex reports 75 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

From December 1986 until April 1987 ground‐based microwave observations of the diurnal variation of mesospheric ozone were made over Bern, Switzerland. These data were of sufficient quality to define the characteristic diurnal behavior of the ozone mixing ratio during winter and equinoctial conditions. The observed diurnal variation of ozone peaks at ∼74 km, where its amplitude is about a factor of 6. At 65 km the observed diurnal variation is a factor of 3, whereas at 55 km it is only a factor of 1.4. One‐dimensional model calculations accurately reproduce the relative diurnal variation of ozone at equinox, suggesting that the model value of the ozone photolysis rate coefficient is accurate to better than 10%. For winter conditions, however, the model underpredicts the observed relative diurnal variation by a factor of 2; a major part of this discrepancy is due to an observed postmidnight increase in ozone. Various suggested changes in model parameters to better reproduce the ozone abundance vertical profile result in only small differences in the relative diurnal variation, indicating that these observations do not provide a sensitive test of the mesopheric chemistry controlling the abundance of odd oxygen.

Key concepts: Diurnal temperature variation, Atmospheric sciences, Ozone, Environmental science, Mesosphere, Mixing ratio, Microwave Limb Sounder, Equinox

Related papers

Back to paper searchBrowse research topicsOriginal source
Diurnal variations of mesospheric ozone obtained by ground‐based microwave radiometry — Research Paper | ScholarLens