2011Contributions to Plasma PhysicsRequires access

Diagnostics Development for Steady State Operation of the Stellarator Wendelstein 7‐X

R. Burhenn, J. Baldzuhn, W. Biel, H. Dreier, M. Endler, R. Jiménez‐Gömez, K. Grosser, H. J. Hartfuß, Diane Hildebrandt, M. Hirsch, R. König, P. Kornejew, M. Krychowiak, H. P. Laqua, M. Laux, J. W. Oosterbeek, E. Pasch, W. Schneider, H. Thomsen, A. Weller, Andreas Werner, R. C. Wolf, D. Zhang

Open publisher page 8 citations

Abstract

Abstract The gain in experience with long‐pulse operation under fusion relevant plasma conditions is an important step towards successful sustainment of future steady state reactor plasmas. The stellarator Wendelstein 7‐X (W7‐X) [1], presently being under construction, is already equipped with a superconducting coil system and principally capable of quasi‐continuous operation. Like other long pulse devices, W7‐X is faced with new enhanced technical requirements which have to be met by plasma facing components as well as the diagnostic systems in general. Water‐cooled windows were qualified up to 60 kW/m2 thermal load, and shutters against evaporation of sensitive elements outside the attended time of the diagnostic as well as for baseline control had been developed. Shielding of in‐vessel components against damage by absorption of microwave stray radiation originating from the heating systems appears to be one of the most challenging tasks. Experiments using a microwave test chamber identify critical materials and approved the necessity for careful shielding of both, sensitive diagnostics and cables. Spectroscopic systems for monitoring the impurity content and divertor load as well as for robust density measurement are presented (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

About this research paper

What this paper is about

Abstract The gain in experience with long‐pulse operation under fusion relevant plasma conditions is an important step towards successful sustainment of future steady state reactor plasmas. The stellarator Wendelstein 7‐X (W7‐X) [1], presently being under construction, is already equipped with a superconducting coil system and principally capable of quasi‐continuous operation. Like other long pulse devices, W7‐X is faced with new enhanced technical requirements which have to be met by plasma facing components as well as the diagnostic systems in general. Water‐cooled windows were qualified up to 60 kW/m2 thermal load, and shutters against evaporation of sensitive elements outside the attended time of the diagnostic as well as for baseline control had been developed. Shielding of in‐vessel components against damage by absorption of microwave stray radiation originating from the heating systems appears to be one of the most challenging tasks. Experiments using a microwave test chamber identify critical materials and approved the necessity for careful shielding of both, sensitive diagnostics and cables. Spectroscopic systems for monitoring the impurity content and divertor load as well as for robust density measurement are presented (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The gain in experience with long‐pulse operation under fusion relevant plasma conditions is an important step towards successful sustainment of future steady state reactor plasmas. The stellarator Wendelstein 7‐X (W7‐X) [1], presently being under construction, is already equipped with a superconducting coil system and principally capable of quasi‐continuous operation. Like other long pulse devices, W7‐X is faced with new enhanced technical requirements which have to be met by plasma facing components as well as the diagnostic systems in general. Water‐cooled windows were qualified up to 60 kW/m2 thermal load, and shutters against evaporation of sensitive elements outside the attended time of the diagnostic as well as for baseline control had been developed. Shielding of in‐vessel components against damage by absorption of microwave stray radiation originating from the heating systems appears to be one of the most challenging tasks. Experiments using a microwave test chamber identify critical materials and approved the necessity for careful shielding of both, sensitive diagnostics and cables. Spectroscopic systems for monitoring the impurity content and divertor load as well as for robust density measurement are presented (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Key concepts: Stellarator, Wendelstein 7-X, Nuclear engineering, Divertor, Electromagnetic shielding, Microwave, Plasma, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnostics Development for Steady State Operation of the Stellarator Wendelstein 7‐X — Research Paper | ScholarLens