1976•Journal of Physics G Nuclear PhysicsOpen access

Fluctuation studies of large air showers: the water Cerenkov lateral distribution at approximately 100 m from the axis of showers of primary energy Ep⩾1017eV

D M Edge

Open full text 4 citations

Abstract

The lateral distribution of the signal produced in water Cherenkov detectors by the extensive air showers secondary to primaries of 10 17 eV has been predicted to be sensitive to fluctuations in shower development. This sensitivity should be greatest at small axial distances (<100 m) and with the existing array at Haverah Park it is possible to make measurements at such distances in a limited number of events of primary energy >or approximately=10 17 eV. These measurements show evidence of substantial fluctuations from shower to shower which are shown to be correlated with the time structure of the shower front. The implications of this work are discussed in terms of current models of development.

Open-access reader

About this research paper

What this paper is about

The lateral distribution of the signal produced in water Cherenkov detectors by the extensive air showers secondary to primaries of 10 17 eV has been predicted to be sensitive to fluctuations in shower development. This sensitivity should be greatest at small axial distances (<100 m) and with the existing array at Haverah Park it is possible to make measurements at such distances in a limited number of events of primary energy >or approximately=10 17 eV. These measurements show evidence of substantial fluctuations from shower to shower which are shown to be correlated with the time structure of the shower front. The implications of this work are discussed in terms of current models of development.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The lateral distribution of the signal produced in water Cherenkov detectors by the extensive air showers secondary to primaries of 10 17 eV has been predicted to be sensitive to fluctuations in shower development. This sensitivity should be greatest at small axial distances (<100 m) and with the existing array at Haverah Park it is possible to make measurements at such distances in a limited number of events of primary energy >or approximately=10 17 eV. These measurements show evidence of substantial fluctuations from shower to shower which are shown to be correlated with the time structure of the shower front. The implications of this work are discussed in terms of current models of development.

Key concepts: Cherenkov radiation, Shower, Physics, Air shower, Nuclear physics, Energy (signal processing), Sensitivity (control systems), Detector

Related papers

Back to paper searchBrowse research topicsOriginal source
Fluctuation studies of large air showers: the water Cerenkov lateral distribution at approximately 100 m from the axis of showers of primary energy Ep⩾1017eV — Research Paper | ScholarLens