Abstract

OBJECTIVE: To determine the influence of positive end-expiratory pressure (PEEP) on intracranial pressure and cerebral perfusion pressure. DESIGN: Neurosurgical intensive care patients requiring intracranial pressure monitoring and mechanical ventilation were studied in a randomized, controlled study. SETTING: Tertiary care, neurosurgical intensive care unit. PATIENTS: Eighteen patients were enrolled in the study. Patients had posttraumatic head injuries (n = 9), subarachnoid hemorrhage (n = 7), obstructive hydrocephalus (n = 1), and intracerebral hemorrhage of unknown cause (n = 1). INTERVENTIONS: Patients had PEEP levels of 5, 10, and 15 cm H2O applied to their lungs. MEASUREMENTS AND MAIN RESULTS: Changes in intracranial pressure, mean arterial pressure, and cerebral perfusion pressure were measured. The results were analyzed separately for patients with normal and increased intracranial pressure (> 15 mm Hg). PEEP at 5 cm H2O had no effect on intracranial pressure in the group with normal intracranial pressure. However, PEEP at 10 and 15 cm H2O produced a significant (p < .05) increase in intracranial pressure (1.9 and 1.5 mm Hg, respectively). In the group with increased intracranial pressure, no significant change in intracranial pressure occurred at any of the PEEP levels used. In both groups, cerebral perfusion pressure was unchanged throughout. CONCLUSIONS: In patients with normal intracranial pressure, PEEP at 5 cm H2O did not significantly alter intracranial pressure. The clinical relevance of the intracranial pressure increase at PEEP levels of 10 and 15 cm H2O is questionable because cerebral perfusion pressure did not change and remained > 60 mm Hg. In patients with increased intracranial pressure, higher levels of PEEP did not significantly change intracranial pressure or cerebral perfusion pressure.

About this research paper

What this paper is about

OBJECTIVE: To determine the influence of positive end-expiratory pressure (PEEP) on intracranial pressure and cerebral perfusion pressure. DESIGN: Neurosurgical intensive care patients requiring intracranial pressure monitoring and mechanical ventilation were studied in a randomized, controlled study. SETTING: Tertiary care, neurosurgical intensive care unit. PATIENTS: Eighteen patients were enrolled in the study. Patients had posttraumatic head injuries (n = 9), subarachnoid hemorrhage (n = 7), obstructive hydrocephalus (n = 1), and intracerebral hemorrhage of unknown cause (n = 1). INTERVENTIONS: Patients had PEEP levels of 5, 10, and 15 cm H2O applied to their lungs. MEASUREMENTS AND MAIN RESULTS: Changes in intracranial pressure, mean arterial pressure, and cerebral perfusion pressure were measured. The results were analyzed separately for patients with normal and increased intracranial pressure (> 15 mm Hg). PEEP at 5 cm H2O had no effect on intracranial pressure in the group with normal intracranial pressure. However, PEEP at 10 and 15 cm H2O produced a significant (p < .05) increase in intracranial pressure (1.9 and 1.5 mm Hg, respectively). In the group with increased intracranial pressure, no significant change in intracranial pressure occurred at any of the PEEP levels used. In both groups, cerebral perfusion pressure was unchanged throughout. CONCLUSIONS: In patients with normal intracranial pressure, PEEP at 5 cm H2O did not significantly alter intracranial pressure. The clinical relevance of the intracranial pressure increase at PEEP levels of 10 and 15 cm H2O is questionable because cerebral perfusion pressure did not change and remained > 60 mm Hg. In patients with increased intracranial pressure, higher levels of PEEP did not significantly change intracranial pressure or cerebral perfusion pressure.

Why it matters

OpenAlex reports 215 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine the influence of positive end-expiratory pressure (PEEP) on intracranial pressure and cerebral perfusion pressure. DESIGN: Neurosurgical intensive care patients requiring intracranial pressure monitoring and mechanical ventilation were studied in a randomized, controlled study. SETTING: Tertiary care, neurosurgical intensive care unit. PATIENTS: Eighteen patients were enrolled in the study. Patients had posttraumatic head injuries (n = 9), subarachnoid hemorrhage (n = 7), obstructive hydrocephalus (n = 1), and intracerebral hemorrhage of unknown cause (n = 1). INTERVENTIONS: Patients had PEEP levels of 5, 10, and 15 cm H2O applied to their lungs. MEASUREMENTS AND MAIN RESULTS: Changes in intracranial pressure, mean arterial pressure, and cerebral perfusion pressure were measured. The results were analyzed separately for patients with normal and increased intracranial pressure (> 15 mm Hg). PEEP at 5 cm H2O had no effect on intracranial pressure in the group with normal intracranial pressure. However, PEEP at 10 and 15 cm H2O produced a significant (p < .05) increase in intracranial pressure (1.9 and 1.5 mm Hg, respectively). In the group with increased intracranial pressure, no significant change in intracranial pressure occurred at any of the PEEP levels used. In both groups, cerebral perfusion pressure was unchanged throughout. CONCLUSIONS: In patients with normal intracranial pressure, PEEP at 5 cm H2O did not significantly alter intracranial pressure. The clinical relevance of the intracranial pressure increase at PEEP levels of 10 and 15 cm H2O is questionable because cerebral perfusion pressure did not change and remained > 60 mm Hg. In patients with increased intracranial pressure, higher levels of PEEP did not significantly change intracranial pressure or cerebral perfusion pressure.

Key concepts: Cerebral perfusion pressure, Intracranial pressure, Medicine, Positive end-expiratory pressure, Anesthesia, Mechanical ventilation, Intracranial pressure monitoring, Traumatic brain injury

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of varying levels of positive end-expiratory pressure on intracranial pressure and cerebral perfusion pressure — Research Paper | ScholarLens