Anatomical measurements of the cervical pedicle in a large series of human cervical vertebrae from 48 individuals were obtained to reduce the incidence and severity of complications caused by transpedicular screw placement. The greatest pedicle length was at C-3 and the greatest pedicle width was at C-6. Pedicle width and lateral mass thickness gradually increased from C-3 to C-6. Pedicle height and interpedicular distance increased from C-3 to C-5, and decreased slightly at C-6. The lateral mass-pedicle length was greatest at C-4. The present study found right-left differences for the pedicle-spinous process distance at C-6 (p < 0.05). Pedicle width and height were smaller than those reported in earlier studies, especially at C-3 and C-4, whereas the increasing pedicle widths at C-5 and C-6 were appropriate for pedicle screw fixation.
OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Anatomical measurements of the cervical pedicle in a large series of human cervical vertebrae from 48 individuals were obtained to reduce the incidence and severity of complications caused by transpedicular screw placement. The greatest pedicle length was at C-3 and the greatest pedicle width was at C-6. Pedicle width and lateral mass thickness gradually increased from C-3 to C-6. Pedicle height and interpedicular distance increased from C-3 to C-5, and decreased slightly at C-6. The lateral mass-pedicle length was greatest at C-4. The present study found right-left differences for the pedicle-spinous process distance at C-6 (p < 0.05). Pedicle width and height were smaller than those reported in earlier studies, especially at C-3 and C-4, whereas the increasing pedicle widths at C-5 and C-6 were appropriate for pedicle screw fixation.
Key concepts: Lateral mass, Fixation (population genetics), Anatomy, Cervical spine, Cervical vertebrae, Medicine, Spinous process, Nuclear medicine