Objective measurement of accommodation function using an autorefractometer

H. Goto, Corina van de Pol, Sandor E. Kaupp, Diana Lozano, Joseph Paul

Open full text 0 citations

Abstract

PURPOSE: To evaluate accommodation function among refractive surgery candidates. METHODS: Autorefraction was measured using a Speedy-K autorefractometer (Right MFG, Tokyo, Japan) in 15 corneal refractive surgery candidates (Age 21 to 38). Repeated measurements of refraction 8.5/sec for 10 sec were performed in various accommodative target distances (+0.5 to −3.0 diopters) in the Speedy-K. Accommodation functions were described as accommodation lag and high frequency component (HFC) of accommodation microfluctuation. HFC was reported as a single number ranging from 30 to 70 on the MF-1 accommodation analysis system. RESULTS: Accommodation lag at −3.0D of accommodative demand was 1.88±0.33 diopters and had significant correlation with level of spherical equivalent refraction (R2=0.427, p=0.008). HFC reached minimum at −0.5 diopters of target distance and increased with the accommodation demand up to −3.0 diopters. CONCLUSIONS: The preoperative spherical equivalent refraction in refractive surgery candidates can affect accommodation function and is anticipated to correlate with the symptoms of near vision disturbances immediately after refractive surgery.

About this research paper

What this paper is about

PURPOSE: To evaluate accommodation function among refractive surgery candidates. METHODS: Autorefraction was measured using a Speedy-K autorefractometer (Right MFG, Tokyo, Japan) in 15 corneal refractive surgery candidates (Age 21 to 38). Repeated measurements of refraction 8.5/sec for 10 sec were performed in various accommodative target distances (+0.5 to −3.0 diopters) in the Speedy-K. Accommodation functions were described as accommodation lag and high frequency component (HFC) of accommodation microfluctuation. HFC was reported as a single number ranging from 30 to 70 on the MF-1 accommodation analysis system. RESULTS: Accommodation lag at −3.0D of accommodative demand was 1.88±0.33 diopters and had significant correlation with level of spherical equivalent refraction (R2=0.427, p=0.008). HFC reached minimum at −0.5 diopters of target distance and increased with the accommodation demand up to −3.0 diopters. CONCLUSIONS: The preoperative spherical equivalent refraction in refractive surgery candidates can affect accommodation function and is anticipated to correlate with the symptoms of near vision disturbances immediately after refractive surgery.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate accommodation function among refractive surgery candidates. METHODS: Autorefraction was measured using a Speedy-K autorefractometer (Right MFG, Tokyo, Japan) in 15 corneal refractive surgery candidates (Age 21 to 38). Repeated measurements of refraction 8.5/sec for 10 sec were performed in various accommodative target distances (+0.5 to −3.0 diopters) in the Speedy-K. Accommodation functions were described as accommodation lag and high frequency component (HFC) of accommodation microfluctuation. HFC was reported as a single number ranging from 30 to 70 on the MF-1 accommodation analysis system. RESULTS: Accommodation lag at −3.0D of accommodative demand was 1.88±0.33 diopters and had significant correlation with level of spherical equivalent refraction (R2=0.427, p=0.008). HFC reached minimum at −0.5 diopters of target distance and increased with the accommodation demand up to −3.0 diopters. CONCLUSIONS: The preoperative spherical equivalent refraction in refractive surgery candidates can affect accommodation function and is anticipated to correlate with the symptoms of near vision disturbances immediately after refractive surgery.

Key concepts: Dioptre, Accommodation, Refraction, Optometry, Ophthalmology, Lag, Optics, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Objective measurement of accommodation function using an autorefractometer — Research Paper | ScholarLens