1984Critical Care MedicineRequires access

Effect of Intralipid on measurements of total hemoglobin and oxyhemoglobin in whole blood

Lakshman R. Sehgal, Hansa L. Sehgal, Arthur L. Rosen, Steven A. Gould, Gerald S. Moss

Open publisher page 23 citations

Abstract

A co-oximeter study of whole blood samples containing Intralipid concentrations of 100 to 2000 mg/dl found that the light-scattering effect was greater at lower hematocrits. The methemoglobin reading was affected the most, and led to erroneous displays of total hemoglobin and percent oxyhemoglobin. The O2-content value, however, was accurate over the entire hematocrit and Intralipid concentration range tested. We suggest that an unexplained high methemoglobin value in whole blood samples from patients receiving Intralipid may reflect a light-scattering problem in the instrument.

About this research paper

What this paper is about

A co-oximeter study of whole blood samples containing Intralipid concentrations of 100 to 2000 mg/dl found that the light-scattering effect was greater at lower hematocrits. The methemoglobin reading was affected the most, and led to erroneous displays of total hemoglobin and percent oxyhemoglobin. The O2-content value, however, was accurate over the entire hematocrit and Intralipid concentration range tested. We suggest that an unexplained high methemoglobin value in whole blood samples from patients receiving Intralipid may reflect a light-scattering problem in the instrument.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A co-oximeter study of whole blood samples containing Intralipid concentrations of 100 to 2000 mg/dl found that the light-scattering effect was greater at lower hematocrits. The methemoglobin reading was affected the most, and led to erroneous displays of total hemoglobin and percent oxyhemoglobin. The O2-content value, however, was accurate over the entire hematocrit and Intralipid concentration range tested. We suggest that an unexplained high methemoglobin value in whole blood samples from patients receiving Intralipid may reflect a light-scattering problem in the instrument.

Key concepts: Hematocrit, Methemoglobin, Medicine, Hemoglobin, Whole blood, Anesthesia, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Intralipid on measurements of total hemoglobin and oxyhemoglobin in whole blood — Research Paper | ScholarLens