1999American Journal of RoentgenologyRequires access

Interobserver variability in the interpretation of renal digital subtraction angiography.

Jean-François Paul, I Cherrak, Marie‐Christine Jaulent, Gilles Châtellier, P.-F. Plouin, Patrice Degoulet, Jean‐Claude Gaux

Open publisher page 33 citations

Abstract

OBJECTIVE: Our purpose was to analyze interobserver variability in the interpretation of renal digital subtraction angiography and to describe the main factors associated with observer discrepancies. MATERIALS AND METHODS: Forty-nine cases of unilateral atheromatous renal artery stenosis of more than 60% were quantified first by local investigators in a multicenter study and then by five other radiologists. Differences between radiologists for the minimum diameter (Dmin), the reference diameter (Dref), and the percentage of stenosis of the renal arteries were analyzed. Interpretations by the local investigators were then compared with the gold standard, defined as the mean for the five radiologists. RESULTS: The average SD for estimation of all renal artery stenoses by all radiologists was 7% for stenosis percentage, 0.5 mm for Dmin, and 0.7 mm for Dref. Main discrepancies occurred more frequently in cases of weakly opacified renal artery stenosis and poststenotic dilatation. The observations of local investigators disagreed by more than two SDs (14%) with the gold standard for 11 of 49 cases (22%). CONCLUSION: The accuracy of digital subtraction angiography in renal artery interpretations is poor because of variations in evaluating both Dmin and Dref. Precise and reproducible methods for quantification of renal artery stenosis are required.

About this research paper

What this paper is about

OBJECTIVE: Our purpose was to analyze interobserver variability in the interpretation of renal digital subtraction angiography and to describe the main factors associated with observer discrepancies. MATERIALS AND METHODS: Forty-nine cases of unilateral atheromatous renal artery stenosis of more than 60% were quantified first by local investigators in a multicenter study and then by five other radiologists. Differences between radiologists for the minimum diameter (Dmin), the reference diameter (Dref), and the percentage of stenosis of the renal arteries were analyzed. Interpretations by the local investigators were then compared with the gold standard, defined as the mean for the five radiologists. RESULTS: The average SD for estimation of all renal artery stenoses by all radiologists was 7% for stenosis percentage, 0.5 mm for Dmin, and 0.7 mm for Dref. Main discrepancies occurred more frequently in cases of weakly opacified renal artery stenosis and poststenotic dilatation. The observations of local investigators disagreed by more than two SDs (14%) with the gold standard for 11 of 49 cases (22%). CONCLUSION: The accuracy of digital subtraction angiography in renal artery interpretations is poor because of variations in evaluating both Dmin and Dref. Precise and reproducible methods for quantification of renal artery stenosis are required.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: Our purpose was to analyze interobserver variability in the interpretation of renal digital subtraction angiography and to describe the main factors associated with observer discrepancies. MATERIALS AND METHODS: Forty-nine cases of unilateral atheromatous renal artery stenosis of more than 60% were quantified first by local investigators in a multicenter study and then by five other radiologists. Differences between radiologists for the minimum diameter (Dmin), the reference diameter (Dref), and the percentage of stenosis of the renal arteries were analyzed. Interpretations by the local investigators were then compared with the gold standard, defined as the mean for the five radiologists. RESULTS: The average SD for estimation of all renal artery stenoses by all radiologists was 7% for stenosis percentage, 0.5 mm for Dmin, and 0.7 mm for Dref. Main discrepancies occurred more frequently in cases of weakly opacified renal artery stenosis and poststenotic dilatation. The observations of local investigators disagreed by more than two SDs (14%) with the gold standard for 11 of 49 cases (22%). CONCLUSION: The accuracy of digital subtraction angiography in renal artery interpretations is poor because of variations in evaluating both Dmin and Dref. Precise and reproducible methods for quantification of renal artery stenosis are required.

Key concepts: Medicine, Renal artery stenosis, Digital subtraction angiography, Renal artery, Stenosis, Radiology, Renal Artery Obstruction, Angiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Interobserver variability in the interpretation of renal digital subtraction angiography. — Research Paper | ScholarLens