2014•EntropyOpen access

District Heating Mode Analysis Based on an Air-cooled Combined Heat and Power Station

Pei Li, Zhihua Ge, Zhiping Yang, Yuyong Chen, Yongping Yang

Open full text 14 citations

Abstract

As an important research subject, district heating with combined heat and power (CHP) has significant potential for energy conservation. This paper utilised a 200 MW air-cooled unit as an actual case and presented a design scheme and energy consumption analysis of three typical CHP modes, including the low vacuum mode (LVM), the extraction condensing mode (ECM), and the absorbing heat pump mode (AHPM). The advantages and disadvantages of each mode (including their practical problems) were analysed, and suggestions for the best mode were proposed. The energy consumption of the three heating modes changed with the heating load. When the heating load was increased, the net power of the entire system decreased to different degrees. In this paper, the energy conservation effect of the LVM was the most ideal, followed by the ECM and the AHPM. Besides, the LVM and AHPM were able to supply larger heat loads than the ECM, which was limited by the minimum cooling flow of the low pressure cylinder. Furthermore, in order to get a more general conclusion, a similar case with an air-cooled 300 MW unit is studied, showing that the fuel consumption levels of ECM and AHPM have changed.

Open-access reader

About this research paper

What this paper is about

As an important research subject, district heating with combined heat and power (CHP) has significant potential for energy conservation. This paper utilised a 200 MW air-cooled unit as an actual case and presented a design scheme and energy consumption analysis of three typical CHP modes, including the low vacuum mode (LVM), the extraction condensing mode (ECM), and the absorbing heat pump mode (AHPM). The advantages and disadvantages of each mode (including their practical problems) were analysed, and suggestions for the best mode were proposed. The energy consumption of the three heating modes changed with the heating load. When the heating load was increased, the net power of the entire system decreased to different degrees. In this paper, the energy conservation effect of the LVM was the most ideal, followed by the ECM and the AHPM. Besides, the LVM and AHPM were able to supply larger heat loads than the ECM, which was limited by the minimum cooling flow of the low pressure cylinder. Furthermore, in order to get a more general conclusion, a similar case with an air-cooled 300 MW unit is studied, showing that the fuel consumption levels of ECM and AHPM have changed.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As an important research subject, district heating with combined heat and power (CHP) has significant potential for energy conservation. This paper utilised a 200 MW air-cooled unit as an actual case and presented a design scheme and energy consumption analysis of three typical CHP modes, including the low vacuum mode (LVM), the extraction condensing mode (ECM), and the absorbing heat pump mode (AHPM). The advantages and disadvantages of each mode (including their practical problems) were analysed, and suggestions for the best mode were proposed. The energy consumption of the three heating modes changed with the heating load. When the heating load was increased, the net power of the entire system decreased to different degrees. In this paper, the energy conservation effect of the LVM was the most ideal, followed by the ECM and the AHPM. Besides, the LVM and AHPM were able to supply larger heat loads than the ECM, which was limited by the minimum cooling flow of the low pressure cylinder. Furthermore, in order to get a more general conclusion, a similar case with an air-cooled 300 MW unit is studied, showing that the fuel consumption levels of ECM and AHPM have changed.

Key concepts: Energy conservation, Energy consumption, Power (physics), Cylinder, Mode (computer interface), Mechanics, Environmental science, Automotive engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
District Heating Mode Analysis Based on an Air-cooled Combined Heat and Power Station — Research Paper | ScholarLens