Comparative molecular analysis of loss of heterozygosity in adenocarcinoma in bile duct brushings and corresponding surgical pathology specimens

N. Paul Ohori, Melissa H. Fowler, Patricia A. Swalsky, Rekha Pal, James W. Thompson, Sydney Finkelstein

Open full text 10 citations

Abstract

BACKGROUND: Bile duct brushing is the procedure of choice for the assessment of neoplasia of the biliary and pancreatic ducts. Conventional cytopathologic evaluation has been reported to have high specificity but relatively low sensitivity. Although a number of molecular studies regarding biliary tract tissue specimens have been performed, to the authors' knowledge their precise applicability to cytopathology specimens has not been critically analyzed. METHODS: Bile duct brushing specimens with the cytopathologic diagnosis of "suspicious" or "positive for malignant cells" along with corresponding surgical pathology specimens demonstrating adenocarcinoma were searched for in the files of UPMC-Presbyterian Hospital for the years 1990-1996. Tumor cells from representative cytopathology and histology slides were microdissected and analyzed for loss of heterozygosity (LOH) in a panel of microsatellite markers. The results obtained from cytopathologic and surgical pathology specimens were compared. RESULTS: Eight paired surgical and cytopathology cases of adenocarcinoma involving the biliary tract were identified. The fractional allelic loss (FAL) for the surgical specimens (FAL-S) ranged from 12.5-71.4% and the FAL for the cytopathology specimens (FAL-C) ranged from 25-71.4%. However, when evaluating the actual loci of LOH, the concordance rate of the surgical and cytopathology specimens ranged from 71.4-100% (mean, 88.6%). Only 3 of the 8 cases (37.5%) were found to have identical matching of the LOH loci. CONCLUSIONS: Although the overall concordance rate of LOH in biliary cytology and surgical specimens by molecular analysis is relatively high, the issue of molecular tumoral heterogeneity must be considered if clinical decisions are to be based exclusively on cytopathologic analysis.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Bile duct brushing is the procedure of choice for the assessment of neoplasia of the biliary and pancreatic ducts. Conventional cytopathologic evaluation has been reported to have high specificity but relatively low sensitivity. Although a number of molecular studies regarding biliary tract tissue specimens have been performed, to the authors' knowledge their precise applicability to cytopathology specimens has not been critically analyzed. METHODS: Bile duct brushing specimens with the cytopathologic diagnosis of "suspicious" or "positive for malignant cells" along with corresponding surgical pathology specimens demonstrating adenocarcinoma were searched for in the files of UPMC-Presbyterian Hospital for the years 1990-1996. Tumor cells from representative cytopathology and histology slides were microdissected and analyzed for loss of heterozygosity (LOH) in a panel of microsatellite markers. The results obtained from cytopathologic and surgical pathology specimens were compared. RESULTS: Eight paired surgical and cytopathology cases of adenocarcinoma involving the biliary tract were identified. The fractional allelic loss (FAL) for the surgical specimens (FAL-S) ranged from 12.5-71.4% and the FAL for the cytopathology specimens (FAL-C) ranged from 25-71.4%. However, when evaluating the actual loci of LOH, the concordance rate of the surgical and cytopathology specimens ranged from 71.4-100% (mean, 88.6%). Only 3 of the 8 cases (37.5%) were found to have identical matching of the LOH loci. CONCLUSIONS: Although the overall concordance rate of LOH in biliary cytology and surgical specimens by molecular analysis is relatively high, the issue of molecular tumoral heterogeneity must be considered if clinical decisions are to be based exclusively on cytopathologic analysis.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Bile duct brushing is the procedure of choice for the assessment of neoplasia of the biliary and pancreatic ducts. Conventional cytopathologic evaluation has been reported to have high specificity but relatively low sensitivity. Although a number of molecular studies regarding biliary tract tissue specimens have been performed, to the authors' knowledge their precise applicability to cytopathology specimens has not been critically analyzed. METHODS: Bile duct brushing specimens with the cytopathologic diagnosis of "suspicious" or "positive for malignant cells" along with corresponding surgical pathology specimens demonstrating adenocarcinoma were searched for in the files of UPMC-Presbyterian Hospital for the years 1990-1996. Tumor cells from representative cytopathology and histology slides were microdissected and analyzed for loss of heterozygosity (LOH) in a panel of microsatellite markers. The results obtained from cytopathologic and surgical pathology specimens were compared. RESULTS: Eight paired surgical and cytopathology cases of adenocarcinoma involving the biliary tract were identified. The fractional allelic loss (FAL) for the surgical specimens (FAL-S) ranged from 12.5-71.4% and the FAL for the cytopathology specimens (FAL-C) ranged from 25-71.4%. However, when evaluating the actual loci of LOH, the concordance rate of the surgical and cytopathology specimens ranged from 71.4-100% (mean, 88.6%). Only 3 of the 8 cases (37.5%) were found to have identical matching of the LOH loci. CONCLUSIONS: Although the overall concordance rate of LOH in biliary cytology and surgical specimens by molecular analysis is relatively high, the issue of molecular tumoral heterogeneity must be considered if clinical decisions are to be based exclusively on cytopathologic analysis.

Key concepts: Cytopathology, Surgical pathology, Medicine, Concordance, Pathology, Loss of heterozygosity, Adenocarcinoma, Bile duct

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative molecular analysis of loss of heterozygosity in adenocarcinoma in bile duct brushings and corresponding surgical pathology specimens — Research Paper | ScholarLens