2000Clinical & Laboratory HaematologyRequires access

New quantitative parameters on a recently introduced automated blood cell counter - the XE 2100TM

Carol Briggs, Paul Harrison, Donna Grant, Julie Staves, Samuel J. Machin

Open publisher page 124 citations

Abstract

The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count was highly correlated (r = 0.97) with the manual reference count. For counts below 100 x 109/l the 'optical' method and the immunocount gave good a correlation (r = 0.97) optical and impedance counts were also well correlated (r = 0.89). The use of the 'optical' platelet count significantly improves the reliability of low platelet counts. The IG count correlated with visual counts (r = 0.81) and allows the detection of immature cells at an earlier stage in the laboratory process. The introduction of fluorescent flow cytometric analysis allows extended quantification of additional cell populations and so potentially improves screening and monitoring of various pathological conditions.

About this research paper

What this paper is about

The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count was highly correlated (r = 0.97) with the manual reference count. For counts below 100 x 109/l the 'optical' method and the immunocount gave good a correlation (r = 0.97) optical and impedance counts were also well correlated (r = 0.89). The use of the 'optical' platelet count significantly improves the reliability of low platelet counts. The IG count correlated with visual counts (r = 0.81) and allows the detection of immature cells at an earlier stage in the laboratory process. The introduction of fluorescent flow cytometric analysis allows extended quantification of additional cell populations and so potentially improves screening and monitoring of various pathological conditions.

Why it matters

OpenAlex reports 124 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The XE 2100 (Sysmex Corporation) is a cell counter that furthers the technology of fluorescent flow cytometry developed from the earlier range of Sysmex analysers. The new diagnostic features are a nucleated red cell count (NRBC), the ability to measure platelets by impedance as well as an 'optical' platelet count using a fluorescence dye and an immature granulocyte (IG) count. The NRBC count was highly correlated (r = 0.97) with the manual reference count. For counts below 100 x 109/l the 'optical' method and the immunocount gave good a correlation (r = 0.97) optical and impedance counts were also well correlated (r = 0.89). The use of the 'optical' platelet count significantly improves the reliability of low platelet counts. The IG count correlated with visual counts (r = 0.81) and allows the detection of immature cells at an earlier stage in the laboratory process. The introduction of fluorescent flow cytometric analysis allows extended quantification of additional cell populations and so potentially improves screening and monitoring of various pathological conditions.

Key concepts: Flow cytometry, Platelet, Fluorescence, Blood cell, Nuclear medicine, Cell counting, Pathology, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
New quantitative parameters on a recently introduced automated blood cell counter - the XE 2100TM — Research Paper | ScholarLens