1972Separation ScienceRequires access

Foam Fractionation in a Stripping Column

Morris Goldberg, Eliezer Rubin

Open publisher page 12 citations

Abstract

Experiments with stripping foam fractionation columns indicate that within the range of variables studied, stripping lengths of 10 to 150 cm have negligible effect on separation. These experimental results cannot be explained adequately by the transfer unit approach. A physical model is proposed wherein the stripping length consists of two mixing regions and a countercurrent flow region in between. Negligible solute transfer is assumed in the countercurrent flow region. This model is applied to explain the experimental data.

About this research paper

What this paper is about

Experiments with stripping foam fractionation columns indicate that within the range of variables studied, stripping lengths of 10 to 150 cm have negligible effect on separation. These experimental results cannot be explained adequately by the transfer unit approach. A physical model is proposed wherein the stripping length consists of two mixing regions and a countercurrent flow region in between. Negligible solute transfer is assumed in the countercurrent flow region. This model is applied to explain the experimental data.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Experiments with stripping foam fractionation columns indicate that within the range of variables studied, stripping lengths of 10 to 150 cm have negligible effect on separation. These experimental results cannot be explained adequately by the transfer unit approach. A physical model is proposed wherein the stripping length consists of two mixing regions and a countercurrent flow region in between. Negligible solute transfer is assumed in the countercurrent flow region. This model is applied to explain the experimental data.

Key concepts: Countercurrent exchange, Stripping (fiber), Fractionation, Range (aeronautics), Flow (mathematics), Chromatography, Mixing (physics), Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Foam Fractionation in a Stripping Column — Research Paper | ScholarLens