1984Journal of Computer Assisted TomographyRequires access

Evaluation of the Performance Characteristics of the PC 4600 Positron Emission Tomograph

Kimberlee Jane Kearfott, Liam Carroll

Open publisher page 48 citations

Abstract

The sensitivity, resolution, linearity, and count rate capability for the PC 4600 positron emission tomograph (PET), a neurological PET with five rings of 96 bismuth germanate crystals, are reported along with details of the design of this system. Phantom studies and preliminary human images demonstrate the clinical potential of this new instrument. Index Terms: Emission computed tomography, apparatus and equipment—Phantoms—Bismuth germanate—Emission computed tomography.

About this research paper

What this paper is about

The sensitivity, resolution, linearity, and count rate capability for the PC 4600 positron emission tomograph (PET), a neurological PET with five rings of 96 bismuth germanate crystals, are reported along with details of the design of this system. Phantom studies and preliminary human images demonstrate the clinical potential of this new instrument. Index Terms: Emission computed tomography, apparatus and equipment—Phantoms—Bismuth germanate—Emission computed tomography.

Why it matters

OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The sensitivity, resolution, linearity, and count rate capability for the PC 4600 positron emission tomograph (PET), a neurological PET with five rings of 96 bismuth germanate crystals, are reported along with details of the design of this system. Phantom studies and preliminary human images demonstrate the clinical potential of this new instrument. Index Terms: Emission computed tomography, apparatus and equipment—Phantoms—Bismuth germanate—Emission computed tomography.

Key concepts: Bismuth germanate, Positron emission tomography, Medicine, Positron emission, Bismuth, Imaging phantom, Nuclear medicine, Tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of the Performance Characteristics of the PC 4600 Positron Emission Tomograph — Research Paper | ScholarLens