Cardiac-phase filtering in intracardiac particle image velocimetry
R. Aidan Jamison, Andreas Fouras, Robert J. Bryson‐Richardson
Abstract
Open-access reader
R. Aidan Jamison, Andreas Fouras, Robert J. Bryson‐Richardson
Abstract
Open-access reader
The ability to accurately measure velocity within the embryonic zebrafish heart, at high spatial and temporal resolution, enables further insight into the effects of hemodynamics on heart development. Unfortunately, currently available techniques are unable to provide the required resolution, both spatial and temporal, for detailed analysis. Advances in imaging hardware are allowing bright field imaging combined with particle image velocimetry to become a viable technique for the broader community at the required spatial and temporal resolutions. While bright field imaging offers the necessary temporal resolution, this approach introduces heart wall artifacts that interfere with accurate velocity measurement. This study presents a technique for cardiac-phase filtering of bright field images to remove the heart wall and improve velocimetry measurements. Velocity measurements were acquired for zebrafish embryos ranging from 3 to 6 days postfertilization. Removal of the heart wall was seen to correct a severe (3-fold) underestimation in velocity measurements obtained without filtering. Additionally, velocimetry measurements were used to quantitatively detect developmental changes in cardiac performance in vivo, investigating both changes in contractile period and maximum velocities present through the ventricular-bulbar valve.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The ability to accurately measure velocity within the embryonic zebrafish heart, at high spatial and temporal resolution, enables further insight into the effects of hemodynamics on heart development. Unfortunately, currently available techniques are unable to provide the required resolution, both spatial and temporal, for detailed analysis. Advances in imaging hardware are allowing bright field imaging combined with particle image velocimetry to become a viable technique for the broader community at the required spatial and temporal resolutions. While bright field imaging offers the necessary temporal resolution, this approach introduces heart wall artifacts that interfere with accurate velocity measurement. This study presents a technique for cardiac-phase filtering of bright field images to remove the heart wall and improve velocimetry measurements. Velocity measurements were acquired for zebrafish embryos ranging from 3 to 6 days postfertilization. Removal of the heart wall was seen to correct a severe (3-fold) underestimation in velocity measurements obtained without filtering. Additionally, velocimetry measurements were used to quantitatively detect developmental changes in cardiac performance in vivo, investigating both changes in contractile period and maximum velocities present through the ventricular-bulbar valve.
Key concepts: Particle image velocimetry, Velocimetry, Temporal resolution, Particle tracking velocimetry, Image resolution, Intracardiac injection, Cardiac cycle, Physics