2006Journal of Speech Language and Hearing ResearchRequires access

Speech Perception for Adults Who Use Hearing Aids in Conjunction With Cochlear Implants in Opposite Ears

Mansze Mok, David B. Grayden, Richard C. Dowell, David M. Lawrence

Open publisher page 177 citations

Abstract

This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between aided thresholds in the nonimplanted ear and speech perception benefit from wearing a hearing aid in conjunction with a cochlear implant in opposite ears. Fourteen adults who used the Nucleus 24 cochlear implant system in 1 ear participated in the study. All participants had either used a hearing aid in the nonimplanted ear for at least 75% of waking hours after cochlear implantation, and/or, hearing loss less than 90 dB HL in the low frequencies in the nonimplanted ear. Speech perception was evaluated in 3 conditions: cochlear implant alone (CI), hearing aid alone (HA), and cochlear implant in conjunction with hearing aid in opposite ears (CIHA). Three speech perception tests were used: consonant-vowel nucleus-consonant (CNC) words in quiet, City University of New York style (CUNY) sentences in coincident signal and noise, and spondees in coincidental and spatially separated signal and noise. Information transmission analyses were performed on the CNC responses. Of the 14 participants tested, 6 showed significant bimodal benefit on open-set speech perception measures and 5 showed benefit on close-set spondees. However, 2 participants showed poorer speech perception with CIHA than CI in at least 1 of the speech perception tests. Results of information transmission analyses showed that bimodal benefit (performance with CIHA minus that with CI) in quiet arises from improved perception of the low frequency components in speech. Results showed that participants with poorer aided thresholds in the mid-to-high frequencies demonstrated greater bimodal benefit. It is possible that the mid-to-high frequency information provided by the hearing aids may be conflicting with the cochlear implants.

About this research paper

What this paper is about

This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between aided thresholds in the nonimplanted ear and speech perception benefit from wearing a hearing aid in conjunction with a cochlear implant in opposite ears. Fourteen adults who used the Nucleus 24 cochlear implant system in 1 ear participated in the study. All participants had either used a hearing aid in the nonimplanted ear for at least 75% of waking hours after cochlear implantation, and/or, hearing loss less than 90 dB HL in the low frequencies in the nonimplanted ear. Speech perception was evaluated in 3 conditions: cochlear implant alone (CI), hearing aid alone (HA), and cochlear implant in conjunction with hearing aid in opposite ears (CIHA). Three speech perception tests were used: consonant-vowel nucleus-consonant (CNC) words in quiet, City University of New York style (CUNY) sentences in coincident signal and noise, and spondees in coincidental and spatially separated signal and noise. Information transmission analyses were performed on the CNC responses. Of the 14 participants tested, 6 showed significant bimodal benefit on open-set speech perception measures and 5 showed benefit on close-set spondees. However, 2 participants showed poorer speech perception with CIHA than CI in at least 1 of the speech perception tests. Results of information transmission analyses showed that bimodal benefit (performance with CIHA minus that with CI) in quiet arises from improved perception of the low frequency components in speech. Results showed that participants with poorer aided thresholds in the mid-to-high frequencies demonstrated greater bimodal benefit. It is possible that the mid-to-high frequency information provided by the hearing aids may be conflicting with the cochlear implants.

Why it matters

OpenAlex reports 177 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between aided thresholds in the nonimplanted ear and speech perception benefit from wearing a hearing aid in conjunction with a cochlear implant in opposite ears. Fourteen adults who used the Nucleus 24 cochlear implant system in 1 ear participated in the study. All participants had either used a hearing aid in the nonimplanted ear for at least 75% of waking hours after cochlear implantation, and/or, hearing loss less than 90 dB HL in the low frequencies in the nonimplanted ear. Speech perception was evaluated in 3 conditions: cochlear implant alone (CI), hearing aid alone (HA), and cochlear implant in conjunction with hearing aid in opposite ears (CIHA). Three speech perception tests were used: consonant-vowel nucleus-consonant (CNC) words in quiet, City University of New York style (CUNY) sentences in coincident signal and noise, and spondees in coincidental and spatially separated signal and noise. Information transmission analyses were performed on the CNC responses. Of the 14 participants tested, 6 showed significant bimodal benefit on open-set speech perception measures and 5 showed benefit on close-set spondees. However, 2 participants showed poorer speech perception with CIHA than CI in at least 1 of the speech perception tests. Results of information transmission analyses showed that bimodal benefit (performance with CIHA minus that with CI) in quiet arises from improved perception of the low frequency components in speech. Results showed that participants with poorer aided thresholds in the mid-to-high frequencies demonstrated greater bimodal benefit. It is possible that the mid-to-high frequency information provided by the hearing aids may be conflicting with the cochlear implants.

Key concepts: Cochlear implant, Audiology, Speech perception, Hearing aid, QUIET, Consonant, Perception, Hearing loss

Related papers

Back to paper searchBrowse research topicsOriginal source
Speech Perception for Adults Who Use Hearing Aids in Conjunction With Cochlear Implants in Opposite Ears — Research Paper | ScholarLens