2002Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

Investigation of reticle defect formation at DUV lithography

Kaustuve Bhattacharyya, William W. Volk, Brian J. Grenon, Darius Brown, Javier Ayala

Open publisher page 23 citations

Abstract

Defect formation on advanced photomasks used for DUV lithography has introduced new challenges at low k1 processes industry wide. Especially at 193-nm scanner exposure, the mask pattern surface, pellicle film and the enclosed space between the pellicle and pattern surface can create a highly reactive environment. This environment can become susceptible to defect growth during repetitive exposure of a mask on DUV lithography systems due to the flow of high energy through the mask. Due to increased number of fields on the wafer, a reticle used at a 300-mm wafer fab receives roughly double the number of exposures without any cool down period, as compared to the reticles in a 200-mm wafer fab. Therefore, 193-nm lithography processes at a 300-mm wafer fab put lithographers and defect engineers into an area of untested mask behavior. During the scope of this investigation, an attenuated phase shift mask (attPSM) was periodically exposed on a 193-nm scanner and the relationship between the number of exposures (i.e., energy passed through the mask during exposures) versus defect growth was developed. Finally, chemical analysis of these defects was performed in order to understand the mechanism of this “growth”.

About this research paper

What this paper is about

Defect formation on advanced photomasks used for DUV lithography has introduced new challenges at low k1 processes industry wide. Especially at 193-nm scanner exposure, the mask pattern surface, pellicle film and the enclosed space between the pellicle and pattern surface can create a highly reactive environment. This environment can become susceptible to defect growth during repetitive exposure of a mask on DUV lithography systems due to the flow of high energy through the mask. Due to increased number of fields on the wafer, a reticle used at a 300-mm wafer fab receives roughly double the number of exposures without any cool down period, as compared to the reticles in a 200-mm wafer fab. Therefore, 193-nm lithography processes at a 300-mm wafer fab put lithographers and defect engineers into an area of untested mask behavior. During the scope of this investigation, an attenuated phase shift mask (attPSM) was periodically exposed on a 193-nm scanner and the relationship between the number of exposures (i.e., energy passed through the mask during exposures) versus defect growth was developed. Finally, chemical analysis of these defects was performed in order to understand the mechanism of this “growth”.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Defect formation on advanced photomasks used for DUV lithography has introduced new challenges at low k1 processes industry wide. Especially at 193-nm scanner exposure, the mask pattern surface, pellicle film and the enclosed space between the pellicle and pattern surface can create a highly reactive environment. This environment can become susceptible to defect growth during repetitive exposure of a mask on DUV lithography systems due to the flow of high energy through the mask. Due to increased number of fields on the wafer, a reticle used at a 300-mm wafer fab receives roughly double the number of exposures without any cool down period, as compared to the reticles in a 200-mm wafer fab. Therefore, 193-nm lithography processes at a 300-mm wafer fab put lithographers and defect engineers into an area of untested mask behavior. During the scope of this investigation, an attenuated phase shift mask (attPSM) was periodically exposed on a 193-nm scanner and the relationship between the number of exposures (i.e., energy passed through the mask during exposures) versus defect growth was developed. Finally, chemical analysis of these defects was performed in order to understand the mechanism of this “growth”.

Key concepts: Reticle, Photomask, Wafer, Lithography, Scanner, Materials science, Photolithography, Next-generation lithography

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation of reticle defect formation at DUV lithography — Research Paper | ScholarLens