2015Regional Anesthesia & Pain MedicineRequires access

Fluoroscopic Evaluation of Contrast Distribution Within the Adductor Canal

Stanley C. Yuan, Neil A. Hanson, David B. Auyong, Daniel Sunghoi Choi, David L. Coy, Wyndam M. Strodtbeck

Open publisher page 16 citations

Abstract

BACKGROUND AND OBJECTIVES: This case series assesses the in vivo spread of contrast within the adductor canal in subjects who recently underwent a total knee arthroplasty. A previous analysis of profound leg weakness with a continuous adductor canal revealed contrast spread from the adductor canal to the femoral triangle with as little as 2 mL of volume. METHODS: We enrolled 10 American Society of Anesthesiologists class II-III subjects. Maximum voluntary isometric contraction was measured to assess quadriceps strength before and after surgery. Contrast was then injected continuously via electronic pump into the adductor canal, and fluoroscopy was used to capture images after 1-mL increments. For analysis, the femur was divided into 8 equidistant sectors between the lesser trochanter and medial epicondyle. RESULTS: Contrast did not reach the level of the lesser trochanter or the medial epicondyle of the femur in any subject. The greatest spread after 5 mL of contrast was 4 sectors. Sixty percent of subjects had contrast spread within either the same sector as the catheter tip or 1 sector distally. No subjects demonstrated additional proximal spread of contrast after 4 mL. CONCLUSIONS: This study reveals that in vivo continuous infusions within the adductor canal spread in both a cephalad and caudad direction in limited fashion. Although a previous report described proximal spread of injectate to the level of the common femoral nerve, this event is infrequent.

About this research paper

What this paper is about

BACKGROUND AND OBJECTIVES: This case series assesses the in vivo spread of contrast within the adductor canal in subjects who recently underwent a total knee arthroplasty. A previous analysis of profound leg weakness with a continuous adductor canal revealed contrast spread from the adductor canal to the femoral triangle with as little as 2 mL of volume. METHODS: We enrolled 10 American Society of Anesthesiologists class II-III subjects. Maximum voluntary isometric contraction was measured to assess quadriceps strength before and after surgery. Contrast was then injected continuously via electronic pump into the adductor canal, and fluoroscopy was used to capture images after 1-mL increments. For analysis, the femur was divided into 8 equidistant sectors between the lesser trochanter and medial epicondyle. RESULTS: Contrast did not reach the level of the lesser trochanter or the medial epicondyle of the femur in any subject. The greatest spread after 5 mL of contrast was 4 sectors. Sixty percent of subjects had contrast spread within either the same sector as the catheter tip or 1 sector distally. No subjects demonstrated additional proximal spread of contrast after 4 mL. CONCLUSIONS: This study reveals that in vivo continuous infusions within the adductor canal spread in both a cephalad and caudad direction in limited fashion. Although a previous report described proximal spread of injectate to the level of the common femoral nerve, this event is infrequent.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND OBJECTIVES: This case series assesses the in vivo spread of contrast within the adductor canal in subjects who recently underwent a total knee arthroplasty. A previous analysis of profound leg weakness with a continuous adductor canal revealed contrast spread from the adductor canal to the femoral triangle with as little as 2 mL of volume. METHODS: We enrolled 10 American Society of Anesthesiologists class II-III subjects. Maximum voluntary isometric contraction was measured to assess quadriceps strength before and after surgery. Contrast was then injected continuously via electronic pump into the adductor canal, and fluoroscopy was used to capture images after 1-mL increments. For analysis, the femur was divided into 8 equidistant sectors between the lesser trochanter and medial epicondyle. RESULTS: Contrast did not reach the level of the lesser trochanter or the medial epicondyle of the femur in any subject. The greatest spread after 5 mL of contrast was 4 sectors. Sixty percent of subjects had contrast spread within either the same sector as the catheter tip or 1 sector distally. No subjects demonstrated additional proximal spread of contrast after 4 mL. CONCLUSIONS: This study reveals that in vivo continuous infusions within the adductor canal spread in both a cephalad and caudad direction in limited fashion. Although a previous report described proximal spread of injectate to the level of the common femoral nerve, this event is infrequent.

Key concepts: Adductor canal, Medicine, Lesser Trochanter, Epicondyle, Femoral nerve, Anatomy, Isometric exercise, Adductor muscles

Related papers

Back to paper searchBrowse research topicsOriginal source
Fluoroscopic Evaluation of Contrast Distribution Within the Adductor Canal — Research Paper | ScholarLens