1999Journal of the Magnetics Society of JapanOpen access

A New Bridge-Type Transformer Using a Three-Leg Core and Its Application to a Removable 5th-Harmonic Voltage Transformer.

S. Okanuma, K. Terauchi, A. Hayasaka, O. Ichinokura

Open full text 0 citations

Abstract

In a previous paper, we proposed a reactor circuit comprising a combination of reactors, single-phase transformers, and resistances. The reactor circuit can remove the 5th-harmonic voltages from its three-phase output voltage. In this paper, we present a new bridge-type three-phase transformer using a three-leg core and a E-form core. Both the line and phase voltages of the three-phase voltage source are applied to the transformer windings. The 5th-harmonic component of the output voltage decreases, because the 5th-harmonic component due to the line voltage and that due to the phase voltage cancel each other out. We describe the operating principle of the bridge-type transformer and its application to a removable 5th-harmonic voltage transformer.

Open-access reader

About this research paper

What this paper is about

In a previous paper, we proposed a reactor circuit comprising a combination of reactors, single-phase transformers, and resistances. The reactor circuit can remove the 5th-harmonic voltages from its three-phase output voltage. In this paper, we present a new bridge-type three-phase transformer using a three-leg core and a E-form core. Both the line and phase voltages of the three-phase voltage source are applied to the transformer windings. The 5th-harmonic component of the output voltage decreases, because the 5th-harmonic component due to the line voltage and that due to the phase voltage cancel each other out. We describe the operating principle of the bridge-type transformer and its application to a removable 5th-harmonic voltage transformer.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In a previous paper, we proposed a reactor circuit comprising a combination of reactors, single-phase transformers, and resistances. The reactor circuit can remove the 5th-harmonic voltages from its three-phase output voltage. In this paper, we present a new bridge-type three-phase transformer using a three-leg core and a E-form core. Both the line and phase voltages of the three-phase voltage source are applied to the transformer windings. The 5th-harmonic component of the output voltage decreases, because the 5th-harmonic component due to the line voltage and that due to the phase voltage cancel each other out. We describe the operating principle of the bridge-type transformer and its application to a removable 5th-harmonic voltage transformer.

Key concepts: Delta-wye transformer, Distribution transformer, Isolation transformer, Transformer, Linear variable differential transformer, Electrical engineering, Voltage, Energy efficient transformer

Related papers

Back to paper searchBrowse research topicsOriginal source
A New Bridge-Type Transformer Using a Three-Leg Core and Its Application to a Removable 5th-Harmonic Voltage Transformer. — Research Paper | ScholarLens