The E.M.F.-Temperature Calibration of Platinum, 10% Rhodium-Platinum and Platinum, 13% Rhodium-Platinum Thermocouples over the Temperature Range 0 -1,760 C

C R Barber

Open publisher page 12 citations

Abstract

E M.F -temperature reference tables are given for platinum, 10% rhodium-platinum and platinum, 13% rhodium-platinum thermocouples over the range from 0° to 1,760° C. The tables are based on the calibration of twelve thermocouples of each kind, six from each of two manufacturers. Each set of six thermocouples comprised two samples from each of three batches of wire The calibrations are in terms of the International Temperature Scale as revised at the Ninth General Conference of Weights and Measures held in Paris in October 1948 The methods of intercomparison between the thermocouples and the various interpolation instruments specified in the International Temperature Scale are described. It is shown that the difference between the new tables and the old are mainly due to changes in the International Temperature Scale, and that the new tables represent the shape of the E.M.F.-temperature characteristics of the thermocouples of either make sufficiently closely to give interpolation between calibration points with accuracy within ±1° C up to 1,063° C., ±2° C. up to 1,550° C., and ±3° C. above this temperature.

About this research paper

What this paper is about

E M.F -temperature reference tables are given for platinum, 10% rhodium-platinum and platinum, 13% rhodium-platinum thermocouples over the range from 0° to 1,760° C. The tables are based on the calibration of twelve thermocouples of each kind, six from each of two manufacturers. Each set of six thermocouples comprised two samples from each of three batches of wire The calibrations are in terms of the International Temperature Scale as revised at the Ninth General Conference of Weights and Measures held in Paris in October 1948 The methods of intercomparison between the thermocouples and the various interpolation instruments specified in the International Temperature Scale are described. It is shown that the difference between the new tables and the old are mainly due to changes in the International Temperature Scale, and that the new tables represent the shape of the E.M.F.-temperature characteristics of the thermocouples of either make sufficiently closely to give interpolation between calibration points with accuracy within ±1° C up to 1,063° C., ±2° C. up to 1,550° C., and ±3° C. above this temperature.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

E M.F -temperature reference tables are given for platinum, 10% rhodium-platinum and platinum, 13% rhodium-platinum thermocouples over the range from 0° to 1,760° C. The tables are based on the calibration of twelve thermocouples of each kind, six from each of two manufacturers. Each set of six thermocouples comprised two samples from each of three batches of wire The calibrations are in terms of the International Temperature Scale as revised at the Ninth General Conference of Weights and Measures held in Paris in October 1948 The methods of intercomparison between the thermocouples and the various interpolation instruments specified in the International Temperature Scale are described. It is shown that the difference between the new tables and the old are mainly due to changes in the International Temperature Scale, and that the new tables represent the shape of the E.M.F.-temperature characteristics of the thermocouples of either make sufficiently closely to give interpolation between calibration points with accuracy within ±1° C up to 1,063° C., ±2° C. up to 1,550° C., and ±3° C. above this temperature.

Key concepts: Rhodium, Platinum, Thermocouple, Atmospheric temperature range, Materials science, Chemistry, Analytical Chemistry (journal), Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
The E.M.F.-Temperature Calibration of Platinum, 10% Rhodium-Platinum and Platinum, 13% Rhodium-Platinum Thermocouples over the Temperature Range 0 -1,760 C — Research Paper | ScholarLens