2010Electric Power Components and SystemsRequires access

Investigation on Electromagnetic Transients of Distributed Generation Systems in the Microgrid

D. N. Gaonkar

Open publisher page 13 citations

Abstract

The increasing interconnection of distributed generation sources of diverse technologies to low-voltage grids introduces considerable complexity in its operation and control. The concept of the microgrid is emerging as a solution to this and also to take full advantage of the potential offered by distributed generation. In this article, the performance of a typical microgrid with multiple distributed generation systems in grid-connected and autonomous modes of operation has been investigated through simulation. The developed model of the microgrid consists of a converter-interfaced microturbine generation system, a synchronous-generator-based distributed generation system, and a wind power generation system with an asynchronous generator. Investigation has been carried out to study the typical electromagnetic transients of a microgrid, due to preplanned and unplanned switching events. The performance of the bidirectional grid interface topology for a microturbine generation system in a microgrid is evaluated in this work. It has been observed from the simulation results that the motoring mode operation of the microturbine generation system during starting does not cause any disturbances in the microgrid. The study also indicates that the microgrid can maintain the desired power quality at the point of common coupling.

About this research paper

What this paper is about

The increasing interconnection of distributed generation sources of diverse technologies to low-voltage grids introduces considerable complexity in its operation and control. The concept of the microgrid is emerging as a solution to this and also to take full advantage of the potential offered by distributed generation. In this article, the performance of a typical microgrid with multiple distributed generation systems in grid-connected and autonomous modes of operation has been investigated through simulation. The developed model of the microgrid consists of a converter-interfaced microturbine generation system, a synchronous-generator-based distributed generation system, and a wind power generation system with an asynchronous generator. Investigation has been carried out to study the typical electromagnetic transients of a microgrid, due to preplanned and unplanned switching events. The performance of the bidirectional grid interface topology for a microturbine generation system in a microgrid is evaluated in this work. It has been observed from the simulation results that the motoring mode operation of the microturbine generation system during starting does not cause any disturbances in the microgrid. The study also indicates that the microgrid can maintain the desired power quality at the point of common coupling.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The increasing interconnection of distributed generation sources of diverse technologies to low-voltage grids introduces considerable complexity in its operation and control. The concept of the microgrid is emerging as a solution to this and also to take full advantage of the potential offered by distributed generation. In this article, the performance of a typical microgrid with multiple distributed generation systems in grid-connected and autonomous modes of operation has been investigated through simulation. The developed model of the microgrid consists of a converter-interfaced microturbine generation system, a synchronous-generator-based distributed generation system, and a wind power generation system with an asynchronous generator. Investigation has been carried out to study the typical electromagnetic transients of a microgrid, due to preplanned and unplanned switching events. The performance of the bidirectional grid interface topology for a microturbine generation system in a microgrid is evaluated in this work. It has been observed from the simulation results that the motoring mode operation of the microturbine generation system during starting does not cause any disturbances in the microgrid. The study also indicates that the microgrid can maintain the desired power quality at the point of common coupling.

Key concepts: Microgrid, Distributed generation, Grid, Control engineering, Engineering, Electricity generation, Asynchronous communication, Interconnection

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation on Electromagnetic Transients of Distributed Generation Systems in the Microgrid — Research Paper | ScholarLens