1999Muscle & NerveRequires access

Proximal Martin-Gruber anastomosis mimicking ulnar neuropathy at the elbow

Connie Marras, Gyl Midroni

Open publisher page 34 citations

Abstract

We present a case of Martin-Gruber anastomosis (MGA) mimicking conduction block between the above- and below-elbow sites of ulnar nerve stimulation. We review the anatomical and electrophysiological literature on this subject and discuss its clinical implications. The potential for a MGA to occur very proximally in the forearm and thus mimic ulnar neuropathy at the elbow is underrecognized. We recommend that a check for MGA be performed on all patients with an apparent conduction block at the elbow, and suggest that 3 cm distal to the medial epicondyle may be an optimal below-elbow ulnar nerve stimulation site.

About this research paper

What this paper is about

We present a case of Martin-Gruber anastomosis (MGA) mimicking conduction block between the above- and below-elbow sites of ulnar nerve stimulation. We review the anatomical and electrophysiological literature on this subject and discuss its clinical implications. The potential for a MGA to occur very proximally in the forearm and thus mimic ulnar neuropathy at the elbow is underrecognized. We recommend that a check for MGA be performed on all patients with an apparent conduction block at the elbow, and suggest that 3 cm distal to the medial epicondyle may be an optimal below-elbow ulnar nerve stimulation site.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We present a case of Martin-Gruber anastomosis (MGA) mimicking conduction block between the above- and below-elbow sites of ulnar nerve stimulation. We review the anatomical and electrophysiological literature on this subject and discuss its clinical implications. The potential for a MGA to occur very proximally in the forearm and thus mimic ulnar neuropathy at the elbow is underrecognized. We recommend that a check for MGA be performed on all patients with an apparent conduction block at the elbow, and suggest that 3 cm distal to the medial epicondyle may be an optimal below-elbow ulnar nerve stimulation site.

Key concepts: Elbow, Ulnar nerve, Ulnar neuropathy, Medicine, Forearm, Anatomy, Epicondyle, Anastomosis

Related papers

Back to paper searchBrowse research topicsOriginal source
Proximal Martin-Gruber anastomosis mimicking ulnar neuropathy at the elbow — Research Paper | ScholarLens