2004Materials science forumOpen access

Effect of Experimental Conditions on the Grafting of Maleic Anhydride onto Polyethylene in Extruders

Ana Vera Machado, J. A. Covas

Open full text 0 citations

Abstract

This work investigates the effect of the operating conditions (set temperature and prescribed throughput) on the evolution of the MA grafted content on high density polyethylene along a co-rotating twin screw extruder. Samples were quickly removed from the extruder at relevant axial locations, quenched and subsequently characterized off-line. While grafting was monitored by FTIR, the residual peroxide was determined by gas chromatography. The results show a good correlation between residual peroxide and MA grafted content.

About this research paper

What this paper is about

This work investigates the effect of the operating conditions (set temperature and prescribed throughput) on the evolution of the MA grafted content on high density polyethylene along a co-rotating twin screw extruder. Samples were quickly removed from the extruder at relevant axial locations, quenched and subsequently characterized off-line. While grafting was monitored by FTIR, the residual peroxide was determined by gas chromatography. The results show a good correlation between residual peroxide and MA grafted content.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This work investigates the effect of the operating conditions (set temperature and prescribed throughput) on the evolution of the MA grafted content on high density polyethylene along a co-rotating twin screw extruder. Samples were quickly removed from the extruder at relevant axial locations, quenched and subsequently characterized off-line. While grafting was monitored by FTIR, the residual peroxide was determined by gas chromatography. The results show a good correlation between residual peroxide and MA grafted content.

Key concepts: Maleic anhydride, Materials science, Grafting, Polyethylene, Polymer science, Composite material, Polymer chemistry, Polymer

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Experimental Conditions on the Grafting of Maleic Anhydride onto Polyethylene in Extruders — Research Paper | ScholarLens