2013•Anesthesia & AnalgesiaRequires access

Pulmonary Auscultation in the Operating Room

Clément Hoffmann, Elisabeth Falzone, C. Verret, Pierre Du Pasquier, Thomas Leclerc, Nicolas Donat, Daniel Jost, Stéphane Merat, Guillaume de Saint Maurice, Bernard Lenoir, Yves Auroy, Jean-Pierre Tourtier

Open publisher page 10 citations

Abstract

BACKGROUND: We compared the subjective quality of pulmonary auscultation between 2 acoustic stethoscopes (Holtex Ideal® and Littmann Cardiology III®) and an electronic stethoscope (Littmann 3200®) in the operating room. METHODS: A prospective double-blind randomized study with an evaluation during mechanical ventilation was performed in 100 patients. After each examination, the listeners using a numeric scale (0-10) rated the quality of auscultation. Auscultation quality was compared in patients among stethoscopes with a multilevel mixed-effects linear regression with random intercept (operator effect), adjusted on significant factors in univariate analysis. A significant difference was defined as P < 0.05. RESULTS: One hundred comparative evaluations of pulmonary auscultation were performed. The quality of auscultation was rated 8.2 ± 1.6 for the electronic stethoscope, 7.4 ± 1.8 for the Littmann Cardiology III, and 4.6 ± 1.8 for the Holtex Ideal. Compared with Holtex Ideal, auscultation quality was significantly higher with other stethoscopes (P < 0.0001). Compared with Littmann Cardiology III, auscultation quality was significantly higher with Littmann 3200 electronic stethoscope (β = 0.9 [95% confidence interval, 0.5-1.3]). CONCLUSIONS: An electronic stethoscope can provide a better quality of pulmonary auscultation than acoustic stethoscopes in the operating room, yet with a magnitude of improvement marginally higher than that provided with a high performance acoustic stethoscope. Whether this can translate into a clinically relevant benefit requires further studies.

About this research paper

What this paper is about

BACKGROUND: We compared the subjective quality of pulmonary auscultation between 2 acoustic stethoscopes (Holtex Ideal® and Littmann Cardiology III®) and an electronic stethoscope (Littmann 3200®) in the operating room. METHODS: A prospective double-blind randomized study with an evaluation during mechanical ventilation was performed in 100 patients. After each examination, the listeners using a numeric scale (0-10) rated the quality of auscultation. Auscultation quality was compared in patients among stethoscopes with a multilevel mixed-effects linear regression with random intercept (operator effect), adjusted on significant factors in univariate analysis. A significant difference was defined as P < 0.05. RESULTS: One hundred comparative evaluations of pulmonary auscultation were performed. The quality of auscultation was rated 8.2 ± 1.6 for the electronic stethoscope, 7.4 ± 1.8 for the Littmann Cardiology III, and 4.6 ± 1.8 for the Holtex Ideal. Compared with Holtex Ideal, auscultation quality was significantly higher with other stethoscopes (P < 0.0001). Compared with Littmann Cardiology III, auscultation quality was significantly higher with Littmann 3200 electronic stethoscope (β = 0.9 [95% confidence interval, 0.5-1.3]). CONCLUSIONS: An electronic stethoscope can provide a better quality of pulmonary auscultation than acoustic stethoscopes in the operating room, yet with a magnitude of improvement marginally higher than that provided with a high performance acoustic stethoscope. Whether this can translate into a clinically relevant benefit requires further studies.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: We compared the subjective quality of pulmonary auscultation between 2 acoustic stethoscopes (Holtex Ideal® and Littmann Cardiology III®) and an electronic stethoscope (Littmann 3200®) in the operating room. METHODS: A prospective double-blind randomized study with an evaluation during mechanical ventilation was performed in 100 patients. After each examination, the listeners using a numeric scale (0-10) rated the quality of auscultation. Auscultation quality was compared in patients among stethoscopes with a multilevel mixed-effects linear regression with random intercept (operator effect), adjusted on significant factors in univariate analysis. A significant difference was defined as P < 0.05. RESULTS: One hundred comparative evaluations of pulmonary auscultation were performed. The quality of auscultation was rated 8.2 ± 1.6 for the electronic stethoscope, 7.4 ± 1.8 for the Littmann Cardiology III, and 4.6 ± 1.8 for the Holtex Ideal. Compared with Holtex Ideal, auscultation quality was significantly higher with other stethoscopes (P < 0.0001). Compared with Littmann Cardiology III, auscultation quality was significantly higher with Littmann 3200 electronic stethoscope (β = 0.9 [95% confidence interval, 0.5-1.3]). CONCLUSIONS: An electronic stethoscope can provide a better quality of pulmonary auscultation than acoustic stethoscopes in the operating room, yet with a magnitude of improvement marginally higher than that provided with a high performance acoustic stethoscope. Whether this can translate into a clinically relevant benefit requires further studies.

Key concepts: Stethoscope, Auscultation, Medicine, Heart Auscultation, Cardiology, Internal medicine, Radiology, Electrocardiography

Related papers

Back to paper searchBrowse research topicsOriginal source