The international temperature scale and a redefinition of the kelvin scale
John A. Hall
Abstract
Open-access reader
John A. Hall
Abstract
Open-access reader
The Tenth General Conference of Weights and Measures has accepted a redefinition of the Kelvin (absolute) temperature scale in terms of one fixed point, the triple point of water, to which a value of 273.16° K has been assigned. The International Temperature Scale continues to be defined in terms of 100° between the ice point (0.0100° C below the triple point of water) and the steam point. The relationship between the scales, and the approved designations are set out in a table. Work is being carried out with a view to future improvement of the international scale. It is hoped that it may be found possible to extend the range covered by the resistance thermometer both above and below its present limits of 630.5° C and -182.97° C, the latter temperature being the present lower limit of the international scale. If the resistance thermometer scale can be carried up to 1063° C (the freezing point of gold), it will be possible to eliminate the thermocouple as a standard instrument and so improve both the continuity and reproducibility of the scale.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The Tenth General Conference of Weights and Measures has accepted a redefinition of the Kelvin (absolute) temperature scale in terms of one fixed point, the triple point of water, to which a value of 273.16° K has been assigned. The International Temperature Scale continues to be defined in terms of 100° between the ice point (0.0100° C below the triple point of water) and the steam point. The relationship between the scales, and the approved designations are set out in a table. Work is being carried out with a view to future improvement of the international scale. It is hoped that it may be found possible to extend the range covered by the resistance thermometer both above and below its present limits of 630.5° C and -182.97° C, the latter temperature being the present lower limit of the international scale. If the resistance thermometer scale can be carried up to 1063° C (the freezing point of gold), it will be possible to eliminate the thermocouple as a standard instrument and so improve both the continuity and reproducibility of the scale.
Key concepts: International Temperature Scale of 1990, Scale of temperature, Triple point, Scale (ratio), Thermocouple, Freezing point, Thermometer, Point (geometry)