Studies on Low‐Dose Hydroxyethyl Starch Leukapheresis: Rate of Elimination of HES in vivo and Function of the Harvested Granulocytes in vitro1
Irma O. Szymanski, Richard A. Teno, Jitendra G. Gandhi, Peter E. Newburger
Abstract
Irma O. Szymanski, Richard A. Teno, Jitendra G. Gandhi, Peter E. Newburger
Abstract
We studied the rate of in vivo elimination of hydroxyethyl starch (HES) given during low dose HES leukapheresis in 9 donors and the effect of this procedure on the in vitro function of granulocytes in 3 donors. HES was eliminated more rapidly than has been previously reported for standard leukapheresis. Serum HES declined to one-half of peak concentration between 1 and 2 days and to one-tenth of peak in 23 days. No HES could be detected in serum 90 days after leukapheresis. The function of the harvested granulocytes was compared to that of granulocytes collected just prior to the procedure by measuring superoxide generation, ingestion and cell motility. There was no significant difference in the function of granulocytes harvested by low dose HES leukapheresis compared to those collected by venipuncture before the procedure.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We studied the rate of in vivo elimination of hydroxyethyl starch (HES) given during low dose HES leukapheresis in 9 donors and the effect of this procedure on the in vitro function of granulocytes in 3 donors. HES was eliminated more rapidly than has been previously reported for standard leukapheresis. Serum HES declined to one-half of peak concentration between 1 and 2 days and to one-tenth of peak in 23 days. No HES could be detected in serum 90 days after leukapheresis. The function of the harvested granulocytes was compared to that of granulocytes collected just prior to the procedure by measuring superoxide generation, ingestion and cell motility. There was no significant difference in the function of granulocytes harvested by low dose HES leukapheresis compared to those collected by venipuncture before the procedure.
Key concepts: Leukapheresis, Hydroxyethyl starch, In vivo, In vitro, Venipuncture, Granulocyte, Andrology, Chemistry