2013•American Journal of Clinical PathologyRequires access

Clinically Unsuspected Cryoglobulinemia: Cases That Present as Laboratory Artifact

Jeffrey S. Warren

Open publisher page 13 citations

Abstract

On the basis of anecdotal instances in which atypical laboratory findings suggested the possibility of unsuspected cryoglobulinemia, we applied predetermined criteria to determine how often such findings predict the presence of clinically significant cryoglobulinemia. The laboratory criteria are smeared M-spike (paraprotein) in agarose gel serum protein electrophoresis, precipitated protein at the serum application point of agarose electrophoresis gel, greater than 50% quantitative discrepancy between the densitometrically estimated M-spike and the relevant corresponding serum immunoglobulin isotype concentration from the same specimen, and smeared protein observed on an agarose electrophoresis immunofixation gel. Cases that fulfilled any of these criteria were prospectively collected for 2 years. Brouet types and clinical findings were determined in cases where cryoglobulins were subsequently identified and clinical data available. Among 83 patients in whom any of the above laboratory findings were identified, 52 had subsequent cryoglobulin evaluations. Fourteen of these 52 patients had cryoglobulinemia. Findings indicative of clinically significant cryoglobulinemia were present in 8 of the 10 patients in whom follow-up clinical data were available.

About this research paper

What this paper is about

On the basis of anecdotal instances in which atypical laboratory findings suggested the possibility of unsuspected cryoglobulinemia, we applied predetermined criteria to determine how often such findings predict the presence of clinically significant cryoglobulinemia. The laboratory criteria are smeared M-spike (paraprotein) in agarose gel serum protein electrophoresis, precipitated protein at the serum application point of agarose electrophoresis gel, greater than 50% quantitative discrepancy between the densitometrically estimated M-spike and the relevant corresponding serum immunoglobulin isotype concentration from the same specimen, and smeared protein observed on an agarose electrophoresis immunofixation gel. Cases that fulfilled any of these criteria were prospectively collected for 2 years. Brouet types and clinical findings were determined in cases where cryoglobulins were subsequently identified and clinical data available. Among 83 patients in whom any of the above laboratory findings were identified, 52 had subsequent cryoglobulin evaluations. Fourteen of these 52 patients had cryoglobulinemia. Findings indicative of clinically significant cryoglobulinemia were present in 8 of the 10 patients in whom follow-up clinical data were available.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

On the basis of anecdotal instances in which atypical laboratory findings suggested the possibility of unsuspected cryoglobulinemia, we applied predetermined criteria to determine how often such findings predict the presence of clinically significant cryoglobulinemia. The laboratory criteria are smeared M-spike (paraprotein) in agarose gel serum protein electrophoresis, precipitated protein at the serum application point of agarose electrophoresis gel, greater than 50% quantitative discrepancy between the densitometrically estimated M-spike and the relevant corresponding serum immunoglobulin isotype concentration from the same specimen, and smeared protein observed on an agarose electrophoresis immunofixation gel. Cases that fulfilled any of these criteria were prospectively collected for 2 years. Brouet types and clinical findings were determined in cases where cryoglobulins were subsequently identified and clinical data available. Among 83 patients in whom any of the above laboratory findings were identified, 52 had subsequent cryoglobulin evaluations. Fourteen of these 52 patients had cryoglobulinemia. Findings indicative of clinically significant cryoglobulinemia were present in 8 of the 10 patients in whom follow-up clinical data were available.

Key concepts: Cryoglobulinemia, Cryoglobulins, Cryoglobulin, Serum protein electrophoresis, Immunofixation, Medicine, Agarose gel electrophoresis, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinically Unsuspected Cryoglobulinemia: Cases That Present as Laboratory Artifact — Research Paper | ScholarLens