2014Korean Journal of AnesthesiologyOpen access

Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery?

Du Gyun Yun, Jong In Han, Dong Yeon Kim, Jong Hak Kim, Youn Jin Kim, Rack Kyung Chung

Open full text 2 citations

Abstract

BACKGROUND: The present study will focus on the rationale for the use of small tidal volume with 6 cmH2O positive end expiratory pressure (PEEP) with the changes of arterial oxygen tension, plateau airway pressure, and static lung compliance during one lung ventilation for endoscopic thoracic surgery. METHODS: Forty-three patients were intubated with a double-lumen endobronchial tube. After positioning the patients in the lateral decubitus, one-lung ventilation was started with 100% oxygen, tidal volume 10 ml/kg without PEEP; arterial oxygen tension, plateau airway pressure, and static compliance were checked as baseline values (T0). Fifteen minutes later, same parameters were measured (T15). The tidal volume had changed to 6 ml/kg with 6 cmH2O PEEP. Fifteen minutes later, the same parameters were measured (T30). RESULTS: Oxygen tension had decreased at T15 (282.1 ± 83.4 mmHg) compared to T0 (477.2 ± 82.4 mmHg) (P < 0.0001), but was maintained at T30 (270.4 ± 81.9 mmHg). There was no difference in peak inspiratory pressure at T15 or T30 compared to T0, plateau airway pressure was increased at T15 and T30 (P < 0.05) and static lung compliance was decreased at T15 and T30 (P < 0.0001). CONCLUSIONS: In carrying out one-lung ventilation for thoracic surgery using an endoscope, the addition of a PEEP of 6 cmH2O in the dependent lung, while reducing the tidal volume of 6 ml/kg, both oxygen tension and lung compliance are maintained without increasing the plateau airway pressure. Protective lung ventilation is useful for one lung ventilation.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The present study will focus on the rationale for the use of small tidal volume with 6 cmH2O positive end expiratory pressure (PEEP) with the changes of arterial oxygen tension, plateau airway pressure, and static lung compliance during one lung ventilation for endoscopic thoracic surgery. METHODS: Forty-three patients were intubated with a double-lumen endobronchial tube. After positioning the patients in the lateral decubitus, one-lung ventilation was started with 100% oxygen, tidal volume 10 ml/kg without PEEP; arterial oxygen tension, plateau airway pressure, and static compliance were checked as baseline values (T0). Fifteen minutes later, same parameters were measured (T15). The tidal volume had changed to 6 ml/kg with 6 cmH2O PEEP. Fifteen minutes later, the same parameters were measured (T30). RESULTS: Oxygen tension had decreased at T15 (282.1 ± 83.4 mmHg) compared to T0 (477.2 ± 82.4 mmHg) (P < 0.0001), but was maintained at T30 (270.4 ± 81.9 mmHg). There was no difference in peak inspiratory pressure at T15 or T30 compared to T0, plateau airway pressure was increased at T15 and T30 (P < 0.05) and static lung compliance was decreased at T15 and T30 (P < 0.0001). CONCLUSIONS: In carrying out one-lung ventilation for thoracic surgery using an endoscope, the addition of a PEEP of 6 cmH2O in the dependent lung, while reducing the tidal volume of 6 ml/kg, both oxygen tension and lung compliance are maintained without increasing the plateau airway pressure. Protective lung ventilation is useful for one lung ventilation.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The present study will focus on the rationale for the use of small tidal volume with 6 cmH2O positive end expiratory pressure (PEEP) with the changes of arterial oxygen tension, plateau airway pressure, and static lung compliance during one lung ventilation for endoscopic thoracic surgery. METHODS: Forty-three patients were intubated with a double-lumen endobronchial tube. After positioning the patients in the lateral decubitus, one-lung ventilation was started with 100% oxygen, tidal volume 10 ml/kg without PEEP; arterial oxygen tension, plateau airway pressure, and static compliance were checked as baseline values (T0). Fifteen minutes later, same parameters were measured (T15). The tidal volume had changed to 6 ml/kg with 6 cmH2O PEEP. Fifteen minutes later, the same parameters were measured (T30). RESULTS: Oxygen tension had decreased at T15 (282.1 ± 83.4 mmHg) compared to T0 (477.2 ± 82.4 mmHg) (P < 0.0001), but was maintained at T30 (270.4 ± 81.9 mmHg). There was no difference in peak inspiratory pressure at T15 or T30 compared to T0, plateau airway pressure was increased at T15 and T30 (P < 0.05) and static lung compliance was decreased at T15 and T30 (P < 0.0001). CONCLUSIONS: In carrying out one-lung ventilation for thoracic surgery using an endoscope, the addition of a PEEP of 6 cmH2O in the dependent lung, while reducing the tidal volume of 6 ml/kg, both oxygen tension and lung compliance are maintained without increasing the plateau airway pressure. Protective lung ventilation is useful for one lung ventilation.

Key concepts: Medicine, Positive end-expiratory pressure, Anesthesia, Ventilation (architecture), Cardiothoracic surgery, Tidal volume, Mechanical ventilation, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery? — Research Paper | ScholarLens