2012The Journal of the Acoustical Society of AmericaRequires access

Cavitation micro-bubble behavior in ultrasound field for HIFU therapy enhancement

Yoichiro Matsumoto, Kohei Okita, Shu Takagi

Open publisher page 0 citations

Abstract

The incepted cavitation micro-bubbles at the target tissue are used to enhance tissue heating in High-Intensity Focused Ultrasound therapy. The control of the inertial cavitation is required to achieve the efficient tissue ablation. The high-intensity ultrasound is used to incept a cavitation, so that the duration time is short enough to prevent the tissue coagulation. The low-intensity ultrasound follows just after the high-intensity ultrasound to continuously drive the cavitating micro-bubbles and coagulate the tissue. Following the experiment, we simulate the focusing of ultrasounds through a mixture containing micro-bubbles with considering the size and number density distributions in space. The numerical simulation shows that the heating region coincides with the cavitation incepted region by high-intensity ultrasound where the micro-bubbles are remaining as cavitation nuclei. The numerical results elucidate well the experimental ones.

About this research paper

What this paper is about

The incepted cavitation micro-bubbles at the target tissue are used to enhance tissue heating in High-Intensity Focused Ultrasound therapy. The control of the inertial cavitation is required to achieve the efficient tissue ablation. The high-intensity ultrasound is used to incept a cavitation, so that the duration time is short enough to prevent the tissue coagulation. The low-intensity ultrasound follows just after the high-intensity ultrasound to continuously drive the cavitating micro-bubbles and coagulate the tissue. Following the experiment, we simulate the focusing of ultrasounds through a mixture containing micro-bubbles with considering the size and number density distributions in space. The numerical simulation shows that the heating region coincides with the cavitation incepted region by high-intensity ultrasound where the micro-bubbles are remaining as cavitation nuclei. The numerical results elucidate well the experimental ones.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The incepted cavitation micro-bubbles at the target tissue are used to enhance tissue heating in High-Intensity Focused Ultrasound therapy. The control of the inertial cavitation is required to achieve the efficient tissue ablation. The high-intensity ultrasound is used to incept a cavitation, so that the duration time is short enough to prevent the tissue coagulation. The low-intensity ultrasound follows just after the high-intensity ultrasound to continuously drive the cavitating micro-bubbles and coagulate the tissue. Following the experiment, we simulate the focusing of ultrasounds through a mixture containing micro-bubbles with considering the size and number density distributions in space. The numerical simulation shows that the heating region coincides with the cavitation incepted region by high-intensity ultrasound where the micro-bubbles are remaining as cavitation nuclei. The numerical results elucidate well the experimental ones.

Key concepts: Cavitation, High-intensity focused ultrasound, Ultrasound, Intensity (physics), Materials science, Bubble, Biomedical engineering, Therapeutic ultrasound

Related papers

Back to paper searchBrowse research topicsOriginal source
Cavitation micro-bubble behavior in ultrasound field for HIFU therapy enhancement — Research Paper | ScholarLens